Page
52
of
60
©
2019 Radiocrafts AS
MBUS User Manual (ver 2.01)
MBUS USER MANUAL
Parameter
Addr
(hex)
MBU
S
3
MBU
S
4
Argument
range
Comment
Default/
Factory Setting
TIMEOUT
0x10
✔
✔
0x01-0xFE
Time before modem clear buffer without transmitting
if Buffer size < Length byte (first byte).
IF SLEEP_MODE=3 the same timeout is used to
auto sleep slaves.
Timeout(ms) = 16 * (1)
Some example values:
0
0x00
Not allowed
1
0x01
32ms
2
0x02
48ms
3
0x03
64ms
124
0x7C
2s
249
0xF9
4s
254
0xFE
4,064s
255
0xFF
Not allowed
Modem transmit without timeout when
Buffer size = length byte.
0x7C
Medium access, addressing and network management
NETWORK_ROLE
0x12
✔
✔
0x00 (0): Slave/Meter
0x01 (1): Master/Concentrator
0x02 (2): Repeater
0x01
MAILBOX
0x16
✔
✔
Auto-message and mailbox configuration
0x20: Two Level Auto Message Enable
0x10: Auto Clear standard message flag
0x08: Auto Clear mailbox flag
0x04: Use mailbox only for special messages*
0x02: Check DFC bit before transmission
0x01: Check Accessibility before transmission
*Special messages are:
SND-NR, RSP-UD and ACK
LBT_ENABLE
0x18
✘
✔
0
0x00
Disabled
1
0x01
Enabled
0x00
M_ID1
0x19
✔
✔
0x00-0xFF
Manufacturer ID, first byte
0x0C
M_ID2
0x1A
✔
✔
0x00-0xFF
Manufacturer ID, second byte
0xAE
U_ID1
0x1B
✔
✔
0x00-0xFF
Unique ID, first byte
0x12
U_ID2
0x1C
✔
✔
0x00-0xFF
Unique ID, second byte
0x34
U_ID3
0x1D
✔
✔
0x00-0xFF
Unique ID, third byte
0x56
U_ID4
0x1E
✔
✔
0x00-0xFF
Unique ID, fourth byte
0x78
VER
0x1F
✔
✔
0x00-0xFF
Version
0x01
DEV
0x20
✔
✔
0x00-0xFF
Device
0x07
REPEATER_MAN_ID1
0x21
✔
✔
0x00-0xFF
MBUS3 only. Repeater filter manufacturer ID, first
byte. Filter is off when both REPEATER_MAN_ID1
and REPEATER_MAN_ID2 = 0x00.
0x00
REPEATER_MAN_ID2
0x21
✔
✔
0x00-0xFF
0x00
LBT_RSSI_
THREASHOLD
0x2A
✘
✔
0x32-0x6E
(50-110)
LBT RSSI threashold value measured in -dBm
0x50 (80)
LBT_MAX_ATTEMPT
0x2B
✘
✔
0x03-0x08
0x05