Page
29
of
60
©
2019 Radiocrafts AS
MBUS User Manual (ver 2.01)
MBUS USER MANUAL
Example (continued)
Field
Hex
Comment/Note
PAD1
0x2F 0x2F
Encryption Verification Bytes. Mandatory
DIF
0x01
User data DIF field
VIF
0x02
User data VIF field
DATA
0x03
User data
DATA
0x04
User data
DIF
0x05
User data DIF field
VIF
0x06
User data VIF field
DATA
0x07
User data
DATA
0x08
User data
PAD2
0x2F 0x2F 0x2F
0x2F 0x2F 0x2F
Padding to fill block (16 bytes)
RSSI
-
Optional. Controlled by RSSI_MODE
CRC
-
Optional. Controlled by DATA_INTERFACE
Based on the above this translates to the following packet when sent over UART:
'0x1D 0x72 0x78 0x56 0x34 0x12 0xCD 0xAB 0x01 0x04 0x01 0x00 0x10 0xC5 0x2F
0x2F 0x01 0x02 0x03 0x04 0x05 0x06 0x07 0x08 0x2F 0x2F 0x2F 0x2F 0x2F 0x2F' *)
*) Packet length sent over UART is not identical to packet length over-the-air for the MBUS packet. The difference is
calculated within the module