Z-Wave
®
Vivint Element CT200 Operation Guide
• Scale (2-bits)
The scale field indicates the temperature scale used: 0
indicates Celsius and 1 indicates Fahrenheit
• Bound Size (3-bits)
The size field indicates the number of bytes used for the
temperature filter value. This field must be one (0x01).
• Temperature Filter Lower Bound (8-bit)
The thermostat will report ambient temperature changes for
temperature values less than the lower bound. This field must
be between 0F and 124F By default, this value is 124F (report
all temperature changes)
• Temperature Filter Upper Bound (8-bit)
The thermostat will report ambient temperature changes for
temperature values greater than the upper bound. This field
must be between 0F and 124F By default, this value is 0F
(report all temperature changes)
Thermostat Reporting Filter Report Command Definition
7
6
5
4
3
2
1
0
Command Class = COMMAND_CLASS_CONFIGURATION
Command = CONFIGURATION_SET
Parameter = 0x0A
Precision (0x00)
Scale
Bound Size (0x01)
Temperature Filter Lower Bound
Temperature Filter Upper Bound
• Parameter (8-bit)
The parameter is set to 10 (0x0A) for the temperature
reporting filter.
• Temperature Filter Lower Bound (8-bit)
The thermostat will report ambient temperature changes for
temperature values less than the lower bound. This field must
be between 0F and 124F By default, this value is 124F (report
all temperature changes)
• Temperature Filter Upper Bound (8-bit)
Configuration Parameters Cont.
47
Содержание CT200
Страница 1: ...RTCOA logo sheet 7aug07 VIVINT ELEMENT THERMOSTAT USER GUIDE ...
Страница 3: ...Radio Thermostat Getting Started 3 ...
Страница 7: ...Radio Thermostat Wiring 7 ...
Страница 14: ...Vivint Element CT200 User Guide 3 Setup 14 ...
Страница 17: ...Radio Thermostat Wiring Diagrams 17 ...
Страница 26: ...Vivint Element CT200 User Guide 5 Product Overview 26 ...
Страница 30: ...Vivint Element CT200 User Guide 6 Customization 30 ...
Страница 41: ...Section Title Chapter Radio Thermostat CT200 OPERATION GUIDE Z WAVE REFERENCE 41 ...