1. Temperature Reporting Threshold (8-bit)
This value determines the reporting threshold when association
reporting is enabled Unsupported values are ignored
Value
0
1
2
3
4
Treshhold
Disabled
Disabled
0 5°F
1 0°F
1 5°F
2. HVAC Settings (32-bit)
Byte 1 = HVAC Setup: Normal (0x01) or Heat Pump (0x02)
Byte 2 = Aux Setup (Gas (0x01) or Electric (0x02)) & Number of
Auxiliary Stages (Heat Pump)/Number of Heat Stages
(Normal)
Byte 3 = Number of Heat Pump Stages
Byte 4 = Number of Cool Stages
3. Utility Lock (8-bit)
If set to 0, the utility lock is disabled All other values (1-255) enable
the utility lock
4. C-Wire/Battery Status (8-bit)
If 0x01, the thermostat is powered by a C-wire If 0x02, the
thermostat is powered by batteries
5. Humidity Reporting Threshold (8-bit)
This value determines the reporting threshold when association
reporting is enabled Unsupported values are ignored
6. Auxiliary/Emergency (8-bit)
If set to 0, auxiliary / emergency heat is disabled All other values
(1-255) enable auxiliary / emergency heat This can only be
enabled when the thermostat is set to Heat Pump mode
7. Thermostat Swing Temp
The thermostat swing temperature is in units of 0 5 degrees
Fahrenheit A value of 0x01 is 0 5F and 0x02 is 1 0F The supported
values may vary from thermostat to thermostat but typically the
allowed values are 0 5F (0x01) to 4 0F (0x08)
Configuration Parameters Cont.
45
Содержание CT200
Страница 1: ...RTCOA logo sheet 7aug07 VIVINT ELEMENT THERMOSTAT USER GUIDE ...
Страница 3: ...Radio Thermostat Getting Started 3 ...
Страница 7: ...Radio Thermostat Wiring 7 ...
Страница 14: ...Vivint Element CT200 User Guide 3 Setup 14 ...
Страница 17: ...Radio Thermostat Wiring Diagrams 17 ...
Страница 26: ...Vivint Element CT200 User Guide 5 Product Overview 26 ...
Страница 30: ...Vivint Element CT200 User Guide 6 Customization 30 ...
Страница 41: ...Section Title Chapter Radio Thermostat CT200 OPERATION GUIDE Z WAVE REFERENCE 41 ...