Radio Systems, Inc.

CT-2002 Manual

Page 15

GPS Driver 

Additional Operating Instructions

Setup Programming 

Refer to the dip-switch setting diagram on page 23 to program the hour offset from
GMT for your time zone, to enable the automatic daylight savings time setting,
and to enable 12 or 24 hour operation. 

Note that the unit is shipped with the factory default setting of Eastern Time Zone (5
hours behind GMT), auto daylight savings time switch-over and 12-hour operation. 

The analog clock dip-switch (switch #1) causes the display to flash after recovery
from a satellite signal loss as an operator indication that your analog clocks have
lost time and must be reset. (Digital clocks connected to the GPS Master driver
will automatically update.) After adjusting the time on the analog clock (see ana-
log clock operation), push the start button to cease flashing and resume normal
display. Factory default for this feature is “off”. 

Top-of-Hour Closure

GPS Master driver units (both large and desktop) provide a top-of-hour closure
available as a C-form relay closure for 250 ms, occurring at the top of each hour.
The C-form contacts are available on the rear remote control barrier strip 
connector on pins 15 and 16 (last two terminals on the strip). See Remote
Connection diagram p19 of this manual for connections.

Connections and Installation 

1.  Mount the antenna on a roof or window ledge with a clear view of the sky.

Avoid areas directly under microwave antenna paths, or near dense foliage. 

2.  The antenna plugs into the clock/receiver via a pre-installed RJ-45 telephone

style connector. Up to 150’ of four conductor shielded cable may installed
between the antenna and the receiver. This cable may be user provided, or a
pre-assembled 150’ or 250’ extension cable is available from Radio Systems.
Please note that for any cable run in excess of 150’, in-line balancing RS-485
convertor amplifiers, available from Radio Systems, must be installed. For
wiring specifications, see the attached antenna wiring detail on page 23. 

Содержание CT-2002 Desktop Master Driver

Страница 1: ...CT 2002 Large Display CT 2002 Console Display CT 2002 Desktop Master Driver CT 2002 Large Master Driver CT 2002 Desktop GPS Driver CT 2002 Large GPS Driver Updated June 2006 Applies to units with software versions CT 2005 see TOC page 2 for details Consult factory to upgrade previous firmware releases ...

Страница 2: ......

Страница 3: ... Remote Control Up Timing 8 Down Timing 8 Storing Down Times 8 Recalling Stored Down Times 9 On Power Up 9 Time of Day Set 9 Setting to Slave Display 9 Setup Functions 10 Infrared Remote Control Diagram 12 Master Driver Additional Operating Instructions 13 To Set the Time on clock power up 13 To Adjust the Time 13 Battery Lamp 13 12 24 Hour Operation 14 GPS Driver Additional Operating Instructions...

Страница 4: ... Analog Clock Connections to CT 2002 GPS and Master Models 20 Serial Time of Day Connections from CT 2002 GPS or Master Models 21 Serial Clock Timer Connections between CT 2002 Stand Alone Models 22 GPS Antenna Wiring Diagram 23 CT 2002 GPS Dip Switch Settings Diagram 24 Policies Warranty 25 Repair Policy 25 Return Instructions 25 CT 2002 Upgrades major 1 Slave timer display enabled 2 Timer compar...

Страница 5: ... LED display and the same features set as the desktop and thin units Master GPS Models Provide up timing and output serial Time of Day data in Radio Systems format CT 2002 Desktop Large Installs in Desktop and Large units to provide Master Driver serial master time data to all CT 2002 clocks and timebase to AC 12 analog clocks Unit has an on board ovenized crystal and accepts top of hour and 1 and...

Страница 6: ...e of Day is supplied to the CT 2002 slave mode it will not be possible to enter the Time of Day set mode Setting the time of day can either be done at the master unit or the displayed hours can be offset via the IR Remote Control 1 Press the mode button to select the Time of Day display The Clock LED will illuminate 2 Desktop and Thin models press and hold the STOP and START buttons The Set Led wi...

Страница 7: ...e only the serial data input terminals in parallel use either the terminal strip or RJ 45 connectors see the connections diagram on page 21 3 The SYNC front panel LED will light and the time of day will immediately conform to the master unit readout 4 Time of Day setting is no longer available on this slave display Time of Day setting must be made to the unit providing the serial Time of Day data ...

Страница 8: ...splay in the timer mode and press the MEM 6 button on the IR remote control Confirm that the sync LED on the slave lights and that the slave display shows the timer data from the up stream display unit 6 To return the slave display to none slaving timer stand alone functionality press the RESET button on the IR remote control with the slave display in the timer mode The SYNC LED will extinguish an...

Страница 9: ...ions see page 10 4 Press the Stop Button to stop down timing 5 Press the Start Button to resume down timing 6 Press the Reset Button once to recall the entered down time Repeat steps 3 through 6 as desired 7 Press the Reset Button two times to exit the down mode and to clear the display and return to up timing mode Storing Down Times The IR Remote Control can be used to store up to six down times ...

Страница 10: ...me of Day set mode if serial time of day is being supplied by a master clock or GPS system However the displayed time may be offset up to 23 hours see IR Remote Setup Functions page 10 1 Press the Clock Mode Button to put the CT 2002 into the Clock Mode The Clock Led will illuminate 2 Press the Time of Day set button The Set Led will illuminate 3 Using the numeric keypad on the IR Remote Control e...

Страница 11: ...stems 2 rS2 format and SMPTE SP format SMPTE enable the serial input to read standard SMPTE format no drop frame rS1 enables the serial inputs to read Radio Systems serial time of day format as generated by Radio Systems GPS Master and stand alone clocks rS2 enables the serial inputs to read Radio Systems serial time of day format as well as upstream timer displays Note that in this mode the Mem 6...

Страница 12: ...ime compare 3 See option 6 above Option nine Time compare 4 See option 6 above Option ten Top of Hour Reset Offset A wired remote input is avail able for top of hour reset The default operation is to reset the time of day to 00 min s 00 sec s To reset to a different time use the numeric keypad enter a time minutes and seconds When the displayed time of day is within a 5 minute window of the stored...

Страница 13: ...begin down timing 5 Press the Stop Button to stop down timing 6 Press the Start Button to resume down timing 7 Press the Reset Button once to recall the selected down time Repeat steps 3 through 6 as desired 8 Press the Reset Button two times to exit the down mode return to up timing mode and clear the display Note Stored Down Time 1 can be recalled remotely via parallel remote control wiring See ...

Страница 14: ... button 2 The display will flash To adjust the time Press and release the STOP button to add one second Press and hold the STOP button to add one hour Press and release the RESET button to lose one second Press and hold the RESET button to lose one hour To reset the time Press mode this must be done prior to adjusting the time Display will reset to 12 00 00 and freeze Press the STOP button to adva...

Страница 15: ...d from the factory in the 12 hour mode To change to 24 hour operation consult the corresponding parts layout diagram for CT 2002 Master driver and locate jumper JU 1 For 24 hour operation remove the jumper from the single jumper pin and insert it so that it connects the two jumper pins together The clock must be powered off and on for the mode change to take effect CT 2002 MASTER DRIVER PARTS LAYO...

Страница 16: ...this feature is off Top of Hour Closure GPS Master driver units both large and desktop provide a top of hour closure available as a C form relay closure for 250 ms occurring at the top of each hour The C form contacts are available on the rear remote control barrier strip connector on pins 15 and 16 last two terminals on the strip See Remote Connection diagram p19 of this manual for connections Co...

Страница 17: ...time will be updated and the data lamps re illuminated 3 Front panel master GPS controls cannot be used to set or change the digitally displayed time of day but the time mode may be used to adjust the time on any analog clocks connected and the START STOP and RESET switches may be used in the timer mode See the Analog Clock Connection and Use sec tion for operating details GPS Error Codes These tw...

Страница 18: ...ay setting 1 Set your CT 2002 Master or GPS unit to the correct time Press Stop Start till display blinks Then press mode button 12 00 00 is displayed This is the Set position 2 Set digital clock to future time that all analog clocks are going to be set to Stop Hours Reset Minutes Do Not Start Clock At This Time 3 Connect the analog clock and start it running if it has not started on its own by pu...

Страница 19: ...our To subtract an hour for Standard Time push and hold the RESET button for 3 seconds The analog clocks will stop running for exactly 1 hour then start again 4 Push the START button to resume normal digital clock operation Notes 1 Adjustments made via the CT 2002 Master driver will effect any digital clocks downstream 2 On systems that utilize the AMD 1 analog clock driver all time adjustments sh...

Страница 20: ...Radio Systems Inc CT2002 Manual Page 19 Remote Connections to CT 2002 Clock Timer Models ...

Страница 21: ...Radio Systems Inc CT2002 Manual Page 20 Analog Clock Connections to CT 2002 GPS and Master Models ...

Страница 22: ...Radio Systems Inc CT2002 Manual Page 21 Serial Time of Day Connections from CT2002 GPS or Master Models ...

Страница 23: ...io Systems Inc CT2002 Manual Page 22 Serial Clock Timer Connections between CT2002 stand alone Models Straight thru Time of Day only RJ 45 Display Cable Crossover Time of Day and Timer RJ 45 Display Cable ...

Страница 24: ...S Part No 14411 Logan Township New Jersey USA 1 856 467 8000 www radiosystems com Satellite Receiver Antenna Note The cable used must be shielded with the ground connected to pin 1 on both ends For cable lengths over 150 install Radio Systems RS 485 balancing amplifiers Pin 1 Ground Shield Pin 2 15V Pin 4 1 P P S Pin 6 Data 87654321 6 Flat Patch Cable 6 Flat Patch Cable 250 factory shielded cable ...

Страница 25: ...Radio Systems Inc CT 2002 Manual Page 24 Connection Diagrams CT 2002 GPS Dip Switch Settings ...

Страница 26: ...ring the warranty period there will be no charge for parts or service made to units which show no sign of misuse by customer or lightning caused damage The customer is responsible for the cost of shipping their unit back to Radio Systems for repair During the warranty period shipment of small parts and assemblies may also be made at a charge to the user Emergency shipments of replacement parts and...

Страница 27: ......

Страница 28: ... 856 467 8000 Fax 856 467 3044 601 Heron Drive Logan Township New Jersey 08085 www radiosystems com For Assy Part 14691 rev 06 06 ...

Отзывы: