Recalling Stored Down Times
The IR Remote Control must be used to recall previously stored down times in
locations MEM2 thru MEM6. MEM1 may be recalled either with the IR remote
control or via the wired remote control. See connection diagram page 19.
1.
Press the Timer Button. The Timer Led will illuminate.
2.
Press one of the Store Buttons.
3.
The stored down time will appear on the display. The Down Led will illuminate.
4.
Press the Start Button to begin down timing.
5.
Press the Stop Button to stop down timing.
6.
Press the Start Button to resume down timing.
7.
Press the Reset Button once to recall the selected down time. Repeat steps 3
through 6 as desired.
8.
Press the Reset Button two times to exit the down mode (return to up timing
mode) and clear the display.
On Power up
1.
Units always power up into the time-of-day mode.
2.
If serial data (RS or SMPTE) is supplied (and the correct mode was pre-select-
ed with the IR Remote Control), then the serially supplied time will display.
3.
The clock must be set when using the internal clock base.
Time-of-Day set
The CT-2002 will not enter the Time-of-Day set mode if serial time of day is being
supplied by a master clock or GPS system. However, the displayed time may be
offset up to 23 hours, (see IR Remote Setup Functions - page 10).
1.
Press the Clock Mode Button to put the CT-2002 into the Clock Mode.
The Clock Led will illuminate.
2.
Press the Time-of-Day set button. The Set Led will illuminate.
3.
Using the numeric keypad on the IR Remote Control enter the correct time.
The display will advance to the next digit only if a valid time has been
entered. In the event of an erroneous entry, press the Time-of-Day set button
to start over.
4.
Press start at the correct moment.
Setting the Timer to Act as a Slave Display
Timers can be wired to slave the display of an upstream timer. Consult wiring dia-
gram on page 22 for details.
1. When in timer mode, press the MEM 6 button on the IR remote control. The
“SYNC” LED will illuminate and the timer will display the upstream time
(the slave display must be receiving timer data from and up-stream timer, and
RS2 must be selected in IR setup option three.)
2. Press the Reset Button “when in timer mode” to force the timer to operate as
a local up/down timer. The “SYNC” LED will extinguish and the timer display
will reset to 00:00. Operate the timer as usual.
3. Press the “MEM 6” button on the IR Remote Control to revert to slave timer
readout.
Содержание CT-2002 Desktop Master Driver
Страница 2: ......
Страница 20: ...Radio Systems Inc CT2002 Manual Page 19 Remote Connections to CT 2002 Clock Timer Models ...
Страница 21: ...Radio Systems Inc CT2002 Manual Page 20 Analog Clock Connections to CT 2002 GPS and Master Models ...
Страница 22: ...Radio Systems Inc CT2002 Manual Page 21 Serial Time of Day Connections from CT2002 GPS or Master Models ...
Страница 25: ...Radio Systems Inc CT 2002 Manual Page 24 Connection Diagrams CT 2002 GPS Dip Switch Settings ...
Страница 27: ......