11.7. Auger Calibration
Menu to modify the work time or speed of Auger 1.
10 calibration steps are available, 5 to increase and 5 to decrease, 0 value corresponds to the
factory setting. The calibration affect the current recipe and the operation powers of the Run
Mode and Modulation steps. For each step to set value is increased or decreased by the per cent
value P15 that can be set in Default Settings Menu. This Menu is only visible if P11 is different
from 1.
Auger Calibration Example: P15=10%, Step=-1
Default Values
CO3=2,0
CO4=3,0
CO5=4,0
CO6=5,0
CO7=6,0
C11=1,0
Calibration
Values
CO3
=1,8
CO4
=2,7
CO5
=3,6
CO6
=4,5
CO7
=5,4
C11
=0,9
The calculated values fall within the range defined by the P27 i P05 parameters.
11.8. Combustion Fan Settings
Menu to modify the Combustion fan speed.
The system has 10 calibration’s steps (the 0 value is set by the factory). The calibration affects
the current recipe and the operation powers to the Run Mode and Modulation states. For each
step the value is increased or decreased by the per cent value P16 set in the Default Settings
Menu. This Menu is only visible if P11 is different from 1.
Combustion Fan Calibration Example: P16=5%, Step=+3
Default
Values
UO3=1000
UO4=1200
UO5=1400
UO6=1600
UO7=1800
U11=900
Calibration
values
UO3
=1150
UO4
=1380
UO5
=1610
UO6
=1840
UO7
=2070
U11
=1030
Figure 28. Auger Calibration: Step by step