55
Radijator Inženjering DOO, 36000 Kraljevo, Živojina Lazića Solunca br.6, Srbija
tel. +381 36 399 140, fax. +381 36 399 150,
, e-mail: [email protected]
8. Table of technical data
Type of boiler
BIOmax
PRO 25
BIOmax
PRO 30
CE designation
CE
CE
Class of Boiler according to EN 303-5:2012
V
V
Working Pressure [bar]
3
3
Test Pressure [bar]
4,5
4,5
Volume of combustion chamber [L]
80
80
Volume of water in the boiler [L]
95
95
Cross section of chamber [mm]
160
160
Necessary chimney draft [mbar/Pa]
0,2/20
0,2/20
Boiler temperature (min/max) [°C]
60-90
60-90
Minimum return temperature [°C]
60
60
Efficiency degree at nominal&minimal thermal power [%]
92,89-93,21
92,4-92,7
Nominal Power [kW]
26,73
30,89
Minimum/Maximum Power of Boiler [kW]
7,66-26,73
10,02-30,89
Carbon monoxide (CO) at a nominal heat power [mg/m
3
]
148,63
(10%O
2
)
152,88
(10%O
2
)
Carbon monoxide (CO) at a minimal heat power
[mg/m
3
]
23,84
(10%O
2
)
24,85
(10%O
2
)
Dust at nominal/minimal heat power [mg/m
3
]
11,23
(10%O
2
)
12,42
(10%O
2
)
Conection for hot water boiler from boiler
D1
1“
1“
Connection for cold water boiler
D2
1“
1“
Connections for filing and emptying boiler
D3
½“
½“
Connector for thermal valve and vent pressure
D4
½“
½“
Connection for thermal valve insurance swelling VTO
D5
½“
½“
Connections for probe VTO
D6
½“
½“
Dimensions [mm]
Figure 17.
A
A1
A
S
B
B1
C
D
E
F
G
H
H
S
BIOmax
PRO 25
531
1248
600
913 1360 1360 160 330 1138
250
1466 1317
BIOmax
PRO 30
531
1248
600
913 1360 1360 160 330 1138
250
1466 1317