Station name
Station name can be modified by user (for example to reflect the unit location in the network topo-
logy).
Station location
Station location can be modified by user (for example to reflect the network topology hierarchy).
Date, Time
The internal real-time clock. The clock is set manually or it is synchronized with NTP server and
set for both units.
Time source
Time synchronization source setup. Manual setup or NTP protocol use. For easier diagnostics of
link operation, it is recommended to use the NTP time synchronization.
Adjust time
Manual time setup. Use the dialog box to manually set the current date and time. You can copy
time from browser (local PC).
NTP source IP
IP address of the time synchronization server.
NTP period
Time synchronization interval.
Time zone
Unit Time zone in the format <Configured time zone> (<Used time zone code> <time offset>) ie.:
"Europe/Prague (CEST +2:00)".
Note
When the time zone is changed, the original values set in the unit are kept. The actual
change takes place after OS restart in order to prevent unexpected states related with
local time change.
Adjust time zone
Use the dialog box to set the new time zone. You can copy the time zone from a browser (local
PC), select the time zone code from a list or input time zone string.
The string can be either time zone code from IANA time zone database (ie.: "Europe/Prague") or
the POSIX format (ie.: "CET-01:00:00CEST-02:00:00,M3.5.0/02:00:00,M10.5.0/03:00:00"). The
posix format allows shortened variants usage when default values are used (ie.: "CET", "CET-
1CEST", ...).
The unit will reboot to use the new setting.
RAy3 Microwave Link – © RACOM s.r.o.
88
Configuration