Voltage max [V]
Default >58
Upper threshold of supply voltage. Active if voltage rises above max voltage threshold.
The same SNMP trap (same OID) applies for both Voltage min and max.
RSS [dBm]
Default <-80
Received Signal Strength. Active if RSS drops below RSS threshold.
MSE [dB]
Default >0
Mean Square Error (the inverse to often used SNR - Signal to Noise Ratio). Active if MSE rises
above MSE threshold.
BER [-]
Default >10e
-6
Bit Error Rate is registered at the receiving end of the link - instantaneous value. Active if BER ex-
ceeds the threshold set in this parameter.
Net bitrate [Mbps]
Default >0
The system warning is generated when the current transfer capacity of radio channel is lower than
the threshold set in this parameter.
Air link down
Default on
Interruption of radio link. Active if radio link is interrupted and units can not communicate by Air.
Eth1/Eth2 link down
Default off
Corresponding user Eth link (Eth1/Eth2) on station interrupted.
Note
The "EthX link" system alarm can only be activated if this alarm is Enabled. When the alarm
is not Enabled, the "EthX link" alarm on
screen is always "Ok" regardless of the
current status of the Ethernet link.
WiFi Management
Default on
Warning is generated when WiFi passphrase is not set or WiFi adapter (and Host Access Point) is
permanently enabled (WiFi Force Enable is ON). Parameter can not be changed in web interface
(only through CLI).
Supply voltage out of range
(RAy3-18 only)
Default off.
Active if voltage before boot is outside of unit voltage range (printed on the unit
). In-
dicated also by the system
(no color).
Note
The unit does not fully boot. Re-boot the unit by re-powering it with a proper power supply.