Out octets A, B
The sum of lengths of all Ethernet frames sent from the AVB Class A (or B) Queue not including
frames that are considered Out octets A, B Management by Ingress. The purpose of this counter
is to measure the actual used rate of the shaper for stream data. The actual data rate from any
queue, AVB or not, can be measured with this counter, however.
Out yellow
The number of Yellow frames that egressed this port (i.e., the number of Yellow frames that suc-
cessfully made it through the queue controller).
Out dropped yellow
The number of Yellow frames not counted in "In discards" that are 'head dropped' from an egress
port's queues and the number Out dropped yellow of Yellow frame's 'tail dropped' from an egress
port's queues due to Queue Controller's queue limits.
Frame size histogram counters
Size 64 octets
Total frames received (and/or transmitted) with a length of exactly 64 octets, including those with
errors.
Size 65-127 octets
Total frames received (and/or transmitted) with a length of between 65 and 127 octets inclusive,
including those with errors.
Size 128-255 octets
Total frames received (and/or transmitted) with a length of between 128 and 255 octets inclusive,
including those with errors.
Size 256-511 octets
Total frames received (and/or transmitted) with a length of between 256 and 511 octets inclusive,
including those with errors.
Size 512-1023 octets
Total frames received (and/or transmitted) with a length of between 512 and 1023 octets inclusive,
including those with errors.
Size 1024-max octets
Total frames received (and/or transmitted) with a length of between 1024 and MaxSize (see MTU
parameter) octets inclusive, including those with errors.
––––––––––––––––––
Histogram counters mode
Frame size histogram counters can count received and/or transmitted octets. The mode of histogram
counters is indicated here.
Measure time
This is the time interval, the diff column is valid for. The "diff" column shows the difference of the
actual value of the counters at the moment of pressing the Difference button and the value of the
counters at the moment of pressing the Refresh button.