User’s Manual
27
The input circuit of the OP7200 was designed to use the differential mode in a unique way
to support measuring voltages in an equal range above and below ground. This method
also requires you to move the 0
Ω
jumper (see Figure 11) on the header associated with the
A/D converter inputs (JP4, JP5, JP6, or JP7) from analog ground to the 2.048 V reference
voltage. The input is connected to the even-numbered channel, and the odd-numbered
channel is tied to analog ground. Table 4 provides the bipolar voltage ranges for this setup.
3.4.2 Analog Current Measurements
Table 4. Bipolar Voltages
Min. Voltage
(V)
Max. Voltage
(V)
Amplifier
Gain
mV per Tick
-20.0
+20.0
1
10
-10.0
+10.0
2
5
-5.0
+5.0
4
2.5
-4.0
+4.0
5
2.0
-2.5
+2.5
8
1.25
-2.0
+2.0
10
1.00
-1.25
+1.25
16
0.625
-1.0
+1.0
20
0.500
The A/D converter inputs can also be used with 4–20 mA
current sources by measuring the resulting analog volt-
age drop across a 100
Ω
1% precision resistor placed
between the analog input and analog ground as shown in
Figure 13.
The single-ended scale of 0–2.56 V with a gain of 8 is
used to get an A/D current conversion of 12.5 µA/tick.
Figure 13. Resistor for 4–20 mA
Current Sources
100
W
1%
AIN0AIN7
AGND
Содержание eDisplay OP7200
Страница 1: ...eDisplay OP7200 VGA Operator Control Panel User s Manual 019 0116 060831 J...
Страница 6: ...eDisplay OP7200...
Страница 14: ...8 eDisplay OP7200...
Страница 22: ...16 eDisplay OP7200...
Страница 52: ...46 eDisplay OP7200...
Страница 126: ...120 eDisplay OP7200...
Страница 132: ...126 eDisplay OP7200...
Страница 133: ...User s Manual 127 APPENDIX A SPECIFICATIONS Appendix A provides the specifications for the OP7200...
Страница 152: ...146 eDisplay OP7200...
Страница 168: ...162 eDisplay OP7200...
Страница 172: ...166 eDisplay OP7200...
Страница 174: ......