7
Aiming and Walk Testing
Test Period:
The sensor has a Test mode which allows
it to be aimed and walk tested day or
night.
• Switch the sensor to Test mode by
adjusting the time control to test
setting. Power on sensor.
• During the 60 second warm up period,
the lights will be turned on. During this
time, test that all fixtures and lamps
function properly.
• After the warmup period, the sensor
will keep lights on for 5 seconds
each time it detects movement in its
Detection Zone.
• Once the Detection Zone is tested,
adjust the sensor Time control to
desired standby time.
Start
Finish
Walk Test:
The purpose of the Walk Test is to check
and adjust the coverage pattern.
1. Aim the sensor approximately to cover
the area you desire.
2. Start outside the Detection Zone and
walk across the zone until the lights
go on. As distance from the sensor
increases, it will take more movement
to be detected. For instance, at 10 feet,
a half step will be enough, while at 30
feet, several steps will be necessary.
3. To reduce range tilt sensor down.
Repeat steps #2 and #3 until you are
satisfied with the coverage.
4. After testing is complete, adjust the
time setting to desired setting by
turning time control knob (5 sec to
15 mins).
5. Your sensor is ready for operation. See
the Technical Tips pages if additional
help is needed.