1. Check that the sensor is level from
side to side and pointed at the area
you desire. If unit is tilted, part of the
Detection Zone may be high in the air
over people’s heads.
Solution:
Position sensor exactly level
from side to side.
2. Check that the sensor is not mounted
too high. If mounted above 20 feet,
much of the usable range will be lost.
3. If sensor is painted, make sure there is
no paint on the lens and that the lens
paint mask is removed.
Solution:
Mounting at 8’ to 10’ allows maximum
range.
Technical Tips:
Range appears limited
40’
10
8’-10’
50 Ft
1. Make sure the sensor is installed
on its own dedicated circuit free of
motor loads such as HVAC equipment,
kitchen appliances or garage door
openers.
2. It is not recommended to wire sensors
in parallel. More than one sensor
wired together makes them difficult
to troubleshoot. Disconnect multiple
sensors and test separately.
3. Keep all people completely out of the
detection pattern to make sure the
sensor is not detecting them.
4. Make sure sensor is located below and
as far as possible from its lights. Heat
from the lights may trigger the sensor.
Solution:
Move sensor below and
away from the lights.
Technical Tips:
Lights Turn On and Off Incorrectly