Technical data
EK2
Size, Series
20
60
150
300
450
800
Elastomer insert
D
D
D
D
D
D
Rated torque (Nm)
T
KN
21
75
200
405
660
1100
Max. torque* (Nm)
T
Kmax
42
150
400
810
1350
2150
Overall length (mm)
A
66
78
90
114
126
162
Outside diameter (mm)
B
42
56
66,5
82
102
136,5
Outside diameter with screw head (mm)
B
5
44,5
57
68
85
105
139
Mounting length (mm)
C
25
30
35
45
50
65
Inside diameter range H7 (mm)
D
1/2
8
– 25
12
– 32
19
– 36
20
– 45
28
– 60
32
– 80
Inside diameter of elastomer (mm)
D
E
19,2
26,2
29,2
36,2
46,2
60,5
Clamping screw (ISO 4762)
E
M5
M6
M8
M10
M12
M16
Tightening torque (Nm)
8
15
35
70
120
290
Distance between centers (mm)
F
8,5
10
12
15
17,5
23
Distance (mm)
G
15,5
21
24
29
38
50,5
Hub length (mm)
H
39
46
52,5
66
73
93,5
Moment of inertia (10
-3
kgm²)
J
1
/J
2
0,016
0,05
0,13
0,4
1,1
12
Approx. weight (kg)
0,15
0,35
0,6
1,1
1,7
10
Speed standard (min
-1
)
12500
11000
10000
9000
8000
4000
Max. offset lateral ± (mm)
0,08
0,1
0,12
0,14
0,18
0,2
Max. offset angular ± (°)
0,8
0,8
0,8
0,8
0,8
0,8
Max. offset axial ± (mm)
2
2
2
2
2
2
*Maximum transmittable torque (Nm) of the clamping hub depends on the bore diameter
Series
Ø8
Ø16
Ø19
Ø25
Ø30
Ø32
Ø35
Ø45
Ø50
Ø55
Ø60
Ø65
Ø70
Ø75
Ø80
20
20
35
45
60
60
50
80
100
110
120
150
120
160
180
200
220
300
200
230
300
350
380
420
450
420
480
510
600
660
750
850
800
700
750
800
835
865
900
925
950
1000
Higher torque possible with keyway.
For the design, the torque to be transmitted between the devices is determined with all design guarantees. With this value, the coupling
size is selected according to the rated torque. The hubs of the EK2 have a clamping hub connection to the shaft.
The transferable torques of the clamping hub connection depending on the shaft and hub bore diameter must be considered by the
user.
An overloaded clamping hub connection leads to the formation of sparks with explosion. The
maximum torque to be transmitted from the clamping hub connection must be observed.
R+W EK2 elastomer couplings have an H7 fit. The fit play of the shaft/hub connection must be in the tolerance of 0.01 to 0.05mm.
Elastomer couplings compensate lateral, axial and angular shaft offsets. In the table you will find maximum permissible guide values for
the individual types of relocation. They provide safety to compensate for operational influences such as thermal expansion and/or
foundation reductions.