TEX1000-LCD
30 / 38
User Manual
Rev. 1.1 - 23/06/05
10. Telemetry (Opt.)
In this chapter are described the potentiality introduced from
TEX1000-LCD/TLM
version and the necessary steps for its corrected configuration.
10.1 Telemetry description
The
TEX1000-LCD/TLM
is able to do the managing of the telesignalling through the
sent of alarms and the reception of SMS commands with a GSM modem.
The parameters on which is possible activate the alarms are:
•
Forward power of the
TEX1000-LCD/TLM
(FWD);
•
Reflected power of the
TEX1000-LCD/TLM
(RFL);
•
Audio signal absence
;
•
Mains voltage absence.
For more information on the sent and reception of the SMS messages SMS, see the
chapter 11.
The machine have the following parameters by factory:
ALARMS
TIMES
THRESHOLD
Forward Power (Fwd Pwr)
25 Sec.
Power Good (PwG)
Reflected Power (Rfl Pwr)
25 Sec.
100W
Audio
25 Sec. (
+
5
Min. Start time
1
)
Overtemperature 25
Sec.
72°C
Mains voltage
5 Min. (
Start time
2
)
1
:
The start time (
adjustable
) of 5 min. avoids that the system sends series of alarm messages
when the machine is in switching on state.
2
:
The start time (
adjustable
) of 5 min., delays the MAINS alarm in order to avoid fakes
alarms for short interruptions of mains voltage.
After the Start time the
TEX1000-LCD/TLM
controls the parameters thresholds and
after the time indicated in table, if still present the alarm condition, comes generated
the relative message. It comes, therefore, inserted one new line in the historian of the
alarms stored from the
TEX1000-LCD/TLM
, until to a maximum of six.
In order to visualize the alarm is possible to be connected with the unit and visualize
it through "TELECON" software, moreover comes forwarded via SMS a message of
text with the following information:
•
Station Name;
•
Station ID;
•
List of the measures in alarm.