41 / 54
User Manual
Rev. 1.2- 24/01/11
PTX-DDS
7.4.3.12 Alarms rescuer submenu (
Aresc
)
This menu provides the alarm rescuer of the exciter. For more information about
this menu, please read chapter 7.6.
| |Status:Disable | |
| |AnaLev:-00 dBr| |
| |DigLev:-00 dBr| |
| |MpxLev:-00 dBr| |
| |PilLev:-00 dBr| |
| |CngTmr:000s 000s | |
| |RecTmr:000m 000m | |
| |
Admin
---[Exit]---|
|
Figure 7.29
Status
Visualization of the alarm rescuer status. The status can be
displayed OK (correct function), WARNING (the audio reserve
is not available), FAULT (only MPX signal is present) or Disable
(function disabled).
AnaLev
Selection of the analogic threshold level adjustment expressed in
decibel (dBr). The adjustment of the level is available in step of
0.2 dBr from -18 to 0 dBr.
Diglev
Selection of the digital threshold level adjustment expressed in
decibel (dBr). The adjustment of the level is available in step of
0.2 dBr from -18 to 0 dBr.
MPXlev
Selection of the composite threshold level adjustment expressed
in decibel (dBr). The adjustment of the level is available in step of
0.2 dBr from -18 to 0 dBr.
PILlev
Selection of the pilot tone threshold level adjustment expressed
in decibel (dBr). The adjustment of the level is available in step of
0.2 dBr from -18 to 0 dBr.
CngTmr
Selection of the intervention times for the passing with lower priority
expressed in seconds. The adjustment of the level is available
in step of 1 s from 5 to 200 s. In --- position the parameter is
disabled.
RecTmr
Selection the intervention times for the passing with upper priority
expressed in seconds. The adjustment of the level is available
in step of 1 s from 5 to 200 s. In --- position the parameter is
disabled.