8 / 54
User Manual
Rev. 1.2 - 24/01/11
PTX-DDS
Dip-Switch Set ON
Set OFF
1 (SW1)
- I
2
C Bus disconnected.
- Analogic Input 5 activated.
- Analogic Input 6 activated.
- I
2
C Bus connected.
- Analogic Input 5 deactivated.
- Analogic Input 6 deactivated.
2 (SW1)
Not used
Not used
3 (SW1)
Not used
Not used
4 (SW1)
- Mains Alarm on analogic input 6 activated
- Mains Alarm on analogic input 6
disactivated
5 (SW1)
- RLY1 and RLY2 enabled for power good
output.
- RLY1 and RLY2 enabled for ON/OFF
output.
6 (SW1)
- RLY1 output activated for reflected power
good signalling.
- RLY1 output activated for audio alarm
signalling.
7 (SW1)
Not used
Not used
8 (SW1)
Not used
Not used
1 (SW2)
- Vmeter bar in kHz
- Vmeter bar in “%”
2 (SW2)
Not used
Not used
3 (SW2)
Not used
Not used
4 (SW2)
Not used
Not used
5 (SW2)
Not used
Not used
6 (SW2)
Not used
Not used
7 (SW2)
Not used
Not used
8 (SW2)
Not used
Not used
Table 5.1:
Dip-Switch configurations
5.2.6 How to enable Local mode
Question:
The equipment don’t accept command through Control knob?
Answer:
• Check current mode setting and enable
Local mode
(if not already enabled)
following menu path
Admin
⇒
PgSet
⇒
Loc
⇒
Local
(chap. 7.4.3.2): if left
disabled, the machine will not accept the next commands.
5.2.7 How to enable Remote mode
If you wish to use the telemetry control feature, enable Remote control in the
Admin
⇒
PgSet
⇒
Loc
⇒
Local
menu (see section 7.4.3.2 for details).
Note :
In the
Remote
mode the control knob, except
Remote/Local
(for switching
back to Local mode), are disabled. Operating parameter readings are available.