F35BVC B-Vent Converter - Installation
This component will allow a direct vent fireplace to be vented like a B Vent fireplace.
Installation:
1. Apply Mill-Pac Sealant to outside of 4 inch flue on
fireplace.
2. Bend up lower portion of the Wiring Channel as shown
above. Ensure that it will be at the back of the fireplace.
3. Carefully push B-Vent Converter down onto the 4 inch
and 7 inch collars of the unit until fully seated.
4. Attach the B-Vent Converter with a Screw.
5. (Optional) Install a Decorative Collar Around the base of
the B-Vent Converter.
6. Route the wires through the hole in the back of the
fireplace top as shown above. Secure in place with the
supplied wire retainer and a DT screw. Connect wires
as shown in the diagram above.
7.
Attach Label wire and Wire Retainer to the bottom left
corner at the back of the fireplace. Store Label inside
pedestal base of fireplace.
DO NOT ALLOW LABEL TO TOUCH FAN.
The following test must be performed by the installer before
installation is complete.
1. Close all doors and windows in the room with the fireplace.
2. Turn on all exhaust fans
and the furnace blower.
3. Turn on the fireplace.
Set burner flame to high.
4. Wait for 10 minutes.
5. Check the chimney draft with a
smoke test match at the top of the
slots in the B-Vent Converter.
There must be adequate draft to
draw smoke into the chimney.
Manual Reset
Switch / Sensor
Wiring Channel
Route wires
along back of
fireplace
Apply Mil Pac to
outside of 4 inch flue
Decorative Collar
(Optional)
Connect 4 inch
pipe to venting
Connect 7 inch
Black Pipe
Parts List:
- [1] B-Vent Converter
- [3] DT Screws
- [1] Wire Retainer
- [1] Label Plate c/w wire
- [1] Male Wire Connector
- [1] Female Wire Connector
FOR QUALIFIED INSTALLERS ONLY.
MUST BE INSTALLED VERTICALLY AS SHOWN.
FOLLOW ALL LOCAL CODES.
WARNING: Operation of this appliance when not connected to a properly
installed and maintained venting system or tampering with the blocked
vent shutoff system can result in carbon monoxide (CO) poisoning and
possible death.
Wire Retainer
Wire
Retainer
LABEL
Attach Label Wire and Wire
Retainer to Fireplace.
Store inside Pedestal Base.
DO NOT ALLOW LABEL TO TOUCH FAN
Correct
Draw
Smoke Test
Match
67
Содержание Kingsman FDV451LP
Страница 42: ...Gas Conversion for Modulator PART C 42...
Страница 47: ...Configuration 1 Basic manual HI LO and manual ON OFF capabilities 47...
Страница 48: ...Receiver Module 584 523 521 221 1001 P221SI Receiver Module 584 523 521 221 1001 P221SI 48...
Страница 55: ...Proflame 2 Remote Control 55...
Страница 57: ...57...