7.3 Oil separator change
Warning
The operator must apply all relevant Safety precautions.
As well as removing power and Lockout/Tagout per OSHA procedures.
Procedure
1.
Run the compressor until warm. Stop the compressor, close the air outlet valve and switch off the voltage.
Wait a few minutes and depressurize by unscrewing filler plug (FC) just one turn to permit any pressure in
the system to escape.
2.
Remove the cover (Ac) from the oil tank (AR) by unscrewing the bolts
Oil separator components
3.
Remove the oil separator (OS).
4.
Clean the seat on oil tank (AR).
Place the new separator into the oil tank and replace the vessel cover (Ac) with the bolts. Take care that
no dirt drops into the system. Refit and tighten filler plug (FC).
5.
Remove filler plug (FC).
Fill the oil tank (AR) with fluid until the level reaches the middle of sight-glass (Gl).