Instruction book
2012 2039 28
72
Fluid drain plugs
4.
Collect the fluid and deliver it to the local collection service. Refit and tighten the drain and vent plugs
after draining.
Re-tighten the top connection of the oil cooler.
5.
Remove the oil filter (OF). Clean the seat on the manifold. Oil the gasket of the new filter and screw it into
place. Tighten firmly by hand.
6.
Remove filler plug (FC).
Fill the oil tank (AR) with fluid until the level reaches the filler neck. Take care that no dirt drops into the
system. Refit and tighten filler plug (FC).
7.
Run the compressor loaded for a few minutes. Stop the compressor and wait a few minutes to allow the
fluid to settle.
8.
Depressurise the system by unscrewing filler plug (FC) just one turn to permit any pressure in the system
to escape. Remove the plug.
Add fluid, the fluid level should be between the top of the sight glass (Gl) and the filling point (FC). Tighten
the filler plug.
9.
Reset the service warning after carrying out all service actions in the relevant Service Plan: see