Instruction book
2012 2039 28
65
Checking the fluid level
Position of oil level sight-glass
Regularly check the fluid level. To do so
1. Press stop button (6).
2. A few minutes after stopping, the fluid level should be between the oil filler neck (FC) and the top of the
sight glass (Gl).
3. If the fluid level is too low, push the emergency stop button to avoid the compressor to start unexpectedly.
4. Remove power and Lockout/Tagout per OSHA.
5. Unscrew fluid filler plug (FC) one turn to permit any pressure left in the system to escape. Wait a few
minutes.
6. Remove the plug and add fluid until the level reaches the filler opening.
7. Fit and tighten the plug (FC).
8. Unlock the emergency stop button and press the "Reset key" on the controller before restarting.
Содержание QSI 50
Страница 2: ......
Страница 16: ...Instruction book 2012 2039 28 16 Main components Main components...
Страница 61: ...Instruction book 2012 2039 28 61 Electric cubicle layout fixed speed Electric cubicle layout Variable speed...
Страница 88: ...Instruction book 2012 2039 28 88 Appendix 1 Product Analysis Report...
Страница 91: ...Instruction book 2012 2039 28 91...