Instruction book
2012 2039 28
70
7
Adjustments and servicing procedures
7.1 Air filter
Warning
If you do not replace the filtering element when needed, permanent dirt build-up will
result. This reduces the air inflow to the compressor and could damage the oil
separator and the compressor
Precautions
1.
Never remove the element while the compressor is running.
2.
For minimum downtime, replace the dirty element by a new one.
3.
Discard the element when damaged.
Procedure
1.
Stop the compressor. Switch off the voltage.
2.
Release the snap clips of air filter (1) and remove the dust trap and the air filter element. Clean the trap.
Discard the filter element.
Position of air filter
3.
Fit the new element and the cover.
4.
Reset the air filter service warning.