background image

Section IV - Operating Procedures

20

Quincy Compressor

® 

- QSB/T

2)

START 

- starts the compressor if no major faults

are present (i.e.: open pressure sensor, temperature
sensor, high temperature condition, or overload).

 NOTICE!

The Run status LED will be on to show that a start
cycle is in progress.  The compressor will not start
if the line pressure is above the load point; the
compressor will start when the line pressure drops
below the load point.  If the compressor is waiting
to start, the Run status
 LED will flash rapidly.

3)

STOP - 

initiates a controlled stop on the

compressor.  The stop cycle will take about 5
seconds to complete due to the system unloading
and blowing down prior to stopping the motor.

4)

UP 

and 

DOWN 

are used to select parameters in the

setup menus.

5)

RESET 

- clears fault or service conditions from the

display panel.

 NOTICE!

After a few minutes of inactivity, the control will
return to the default display.

System Indicators

Run status - 

A steady light indicates that the compressor

is running.  If this light is flashing, the compressor is
stopped but can be restarted at any time or, if auto-restart
is enabled, the compressor is about to start.

Load/Unload - 

The left-most digit on the numeric display

will show 

when the compressor is loaded, and 

when

unloaded.

Program Setup Menus

The program setup menus are accessed by pressing the

UP 

and 

DOWN 

keys simultaneously until the LED lamps

on the left start to flash.  When the numeric display
flashes 

-00-

, Release the 

UP 

and 

DOWN 

keys and use the

UP 

key to select the desired menu (01, 02, and 03 are user

menus).

There is a time limit to select the menu number.  If this
time period is exceeded, the control will return to the
standard display mode.

 NOTICE!

The nomenclature on the decal beside the LED’s
does NOT represent the function of the LED in
these menus.

Menu 01 - Basic Operating Adjustments

 NOTICE!

All settings are saved when the display reading is
steady.

LED 1 - 

Use the 

MENU 

key to select the load and unload

pressures (indicated by 

or 

U

 at the left-most digit).  Use

UP 

or 

DOWN 

to adjust.

LED 2 - 

Allows adjustment of the wye-delta (Y/D) time

on the contactor (set to optimum at the factory).  This
should be set to allow the motor to reach full speed before
the contactors switch from wye to delta connection.

LED 3 - 

Auto dual timer setting (in minutes) indicated by

in the left-most digit of the display.  Determines  how

long the compressor will run unloaded before shutting
down.  When the delivery pressure falls below the load
setting after shutting down, the compressor will start up
automatically.

LED 4 - Auto restart delay (in seconds) indicated by 

in

the left-most digit of the display. The compressor will
delay this length of time on power-up, before
automatically starting.  Set to 0 if auto restart is not
required.

 NOTICE!

Auto restart refers to the automatic starting of
the compressor on power application.

Содержание QSB Series

Страница 1: ...s manual contains important safety information and should be made available to all personnel who operate and or maintain this product Carefully read this manual before attempting to operate or perform...

Страница 2: ......

Страница 3: ...III Installation Receiving 12 Moving the Unit to the Installation Site 12 Location 13 Piping Connections 14 Relief Valves 14 Pressure Vessels 14 Electrical 15 Guards 15 Manual Vent and Shutoff Valves...

Страница 4: ...tions 36 Lubrication 37 Fluid Level 37 Fluid Filter 38 Factors Affecting Fluid Life 38 Fluid Analysis Program General 39 QuinSyn PG 40 QuinSyn XP 41 QuinSyn Plus 42 QuinSyn Fluids 43 QuinSyn Flush 44...

Страница 5: ...iod Standard Warranty Quincy Compressor Industrial Screw Products QSB T Rotary Screw Air Compressors Seller s sole obligation on this warranty shall be at its option to repair replace or refund the pu...

Страница 6: ...d IMPORTANT Throughout this manual we have identified key hazards The following symbols identify the level of hazard seriousness DANGER This symbol identifies immediate hazards which will result in se...

Страница 7: ...ld result in the rupturing or explosion of some compressor component Do not change the pressure setting of the pressure relief valve restrict the function of the pressure relief valve or replace the p...

Страница 8: ...sible for typographical errors Spare Parts Ordering Information Quincy Compressor maintains replacement parts for Quincy compressors A parts manual is shipped with all new machines Order parts from yo...

Страница 9: ...Section I General Quincy Compressor QSB T 5 MODEL IDENTIFICATION...

Страница 10: ...ompression cycle of a rotary screw compressor is a continuous process from intake to discharge with no reciprocating mechanisms starting and stopping as found in reciprocating compressors The compress...

Страница 11: ...ompressor of approximately 180 F Water cooled Fluid Coolers Water cooled fluid coolers are of the shell and tube design Fluid passes through the shell transferring its heat to the water flowing throug...

Страница 12: ...inlet valve is held in a closed position preventing the intake of air into the compressor and serving as a check valve preventing reverse air fluid flow through the inlet valve and air filter Auto Dua...

Страница 13: ...f on until the excess demand has been satisfied Again working with the standard Auto Dual control the second machine would time out and turn itself off after the demand dropped Load No Load Optional I...

Страница 14: ...ntrols include the selector switch pressure switch timer high air temperature safety switches solenoid and the various indicator lights Other incoming line voltages are available as options The compre...

Страница 15: ...icates excessive pressure differential across the air fluid separator element It is used to determine separator element change intervals Gauges Hourmeter This gauge indicates actual hours of operation...

Страница 16: ...ng carrier within 15 days of delivery The delivering carrier must prepare a damage report Itemized supporting papers are essential to filing a claim Read the compressor nameplate to be sure the compre...

Страница 17: ...ed exhaust air must be exhausted outside to prevent high temperature conditions in the compressor room If the room is not properly ventilated compressor operating temperatures will increase and cause...

Страница 18: ...sized to protect the system Never change the pressure setting or tamper with the valve Only the relief valve manufacturer or an approved representative is qualified to make such a change DANGER Relie...

Страница 19: ...ide diameter shall have a safety device at the source of supply or branch line to reduce pressure in case of a hose failure These pneumatic safety devices are designed to prevent hoses from whipping w...

Страница 20: ...t least as large as the inlet valve opening and increased several sizes for extremely long piping runs The piping must be leak free and clean after fabrication Compressor Rotation Compressor rotation...

Страница 21: ...Quincy Compressor QSB T 17 THIS PAGE INTENTIONALLY LEFT BLANK...

Страница 22: ...ls and guards are in place and securely mounted Check fuses circuit breakers and thermal overloads for proper size Close the main power disconnect switch and jog the starter switch button to check the...

Страница 23: ...he pressure is displayed in the numeric display NOTICE Aflashing on the digit display accompanied by an LED on the left signifies a faulty sensor eitherthe pressure transducerorthe temperature probe A...

Страница 24: ...essing the UP and DOWN keys simultaneously until the LED lamps on the left start to flash When the numeric display flashes 00 Release the UP and DOWN keys and use the UP key to select the desired menu...

Страница 25: ...dicates compressor model QSF or QSB QMB LED 4 Set the total running hours this should only be adjusted during controller replacement to match recorded time from the previous one Use UP or DOWN to sele...

Страница 26: ...to prevent any backup of air flow into the area to be serviced NEVER depend upon a check valve to isolate the system 3 Open the manual vent valve and wait for the pressure in the system to be complet...

Страница 27: ...Quincy Compressor QSB T 23 THIS PAGE INTENTIONALLY LEFT BLANK...

Страница 28: ...flammable solvent such as gasoline or kerosene for cleaning air filters or compressor parts Safety solvents are available and should be used in accordance with their instructions CAUTION Unusual noise...

Страница 29: ...will stop particles of 10 microns in size This element is replaceable and should not be cleaned Service intervals of the air filter element depends on ambient conditions and should be established by c...

Страница 30: ...from the airend into the seal cavity and appear as a leak If the check valve is stuck closed the seal cavity will not scavenge Replace if necessary Remove the four bolts securing the seal adapter to t...

Страница 31: ...small oven to 350 F Do not preheat in warm oil Apply a thin film of Loctite to the inner diameter of the wear sleeve and immediately install on the compressor shaft using the proper wear sleeve driver...

Страница 32: ...t pressure The pressure switch should unload the compressor by the time it reaches the 20 load point Raising the pressure without changing the compressor speed above factory settings will result in hi...

Страница 33: ...ent check alignment in at least three places after rotating one of the sheaves 120 each time Misalignment comes in three varieties Horizontal angular vertical angular and parallel Sheave alignment sho...

Страница 34: ...checked monthly and confirmed to be within tension requirements listed in the following table If not adjust per instructions on page 32 QSB T 10 30 HP TENSIONING DATA SPRING HEIGHT IN BELT TENSION LBS...

Страница 35: ...of pounds pressure Read at bottom edge of ring Slide the o ring to back to 0 pounds before reusing 5 Compare deflection force with range of forces listed for unit being tested If less than minimum rec...

Страница 36: ...alignment rotate the motor to the opposite end of travel and recheck sheave alignment Note These two alignments should be within 1 16 inch of each other if not realignment is required NOTICE Before th...

Страница 37: ...elts weakening or breaking the tensile cords 7 Rotate drive by hand to help seat belts in sheaves Check motor base it should be level within 5 degrees 8 Tension the belts by turning the jackbolt 2 clo...

Страница 38: ...replaced Install new Teflon bushing and transducer Connect transducer wires to microprocessor and reinstall wire channel cover Replacing Electronic Control Prior to replacing electronic control gathe...

Страница 39: ...THE GROOVE POSITION AND HOLD FLAT SEALING FACE AGAINST O RING 2 BACK OFF NUT BACK OFF LOCKNUT TO ITS UPPERMOST POSITION 3 THREAD INTO PORT THREAD FITTING INTO THE PORT UNTIL THE BACKUP WASHER CONTACT...

Страница 40: ...owering the compressed air discharge temperature to seal the rotor clearances Fluid Specifications We recommend that all Quincy rotary screw compressors be filled with one of the following synthetic f...

Страница 41: ...e design life of the compressor or cause problems with filtration or carryover Consult the Quincy Service Department before changing brands of fluid Fluid Level Fluid level is monitored by a sightglas...

Страница 42: ...tment check for the following which can affect the long life of QuinSyn 1 High operating temperatures 2 Contaminants a Other fluids b Strong Oxidizers such as acids sulfur chlorine burnt fuel i e exha...

Страница 43: ...tory upon completion of the fluid analysis Although QuinSyn fluids are rated by hours of life expectancy under normal operating conditions it is recommended that fluid samples be taken every 500 to 20...

Страница 44: ...to drain water from the reservoir Disposal QuinSyn PG is considered nonhazardous waste Disposal of this fluid should be done in accordance with Local State and Federal regulations Separation of this f...

Страница 45: ...6 Typical Properties of QuinSyn XP ISO 68 Viscosity 100 F ASTM D445 60 0 cSt Viscosity 210 F ASTM D445 9 8 cSt Viscosity Index ASTM D2270 131 Specific Gravity 60 60 0 95 Flash Point ASTM D92 570 F Fir...

Страница 46: ...l stability Excellent oxidative stability Better gas fluid separation Typical Properties of QuinSyn Plus ISO 46 Viscosity 100 F ASTM D445 46 0 cSt Viscosity 210 F ASTM D445 7 5 cSt Viscosity Index AST...

Страница 47: ...mpressors as a factory fill option Extended warranties are not available with the use of QuinSyn IV QuinSyn QuinSyn is a Polyalphaolefin PAO type synthetic fluid Effective November 1 2000 QuinSyn Comp...

Страница 48: ...th mineral oils and QuinSyn synthetic fluids and is highly recommended for use as a flushing fluid when converting to QuinSyn PG from QuinSyn or QuinSyn IV Applications Cleaning fluid for removal of v...

Страница 49: ...ng the following procedure Drain thoroughly as in A and fill with QuinSyn Flush Run the machine for 300 hours and take a fluid sample Send fluid sample to Quincy Compressor Fluid Analysis to determine...

Страница 50: ...ple and send to Quincy Compressor Fluid Analysis to determine if further flushing is needed Continue operating compressor until the results of fluid analysis are known Drain or continue to run compres...

Страница 51: ...eral oils or PAO fluids flush the compressor with QuinSyn Flush following the procedures outlined on page 45 Converting to QuinSyn Plus Normal Machines A Any QuinSyn fluid except QuinSyn PG No flush r...

Страница 52: ...s must be placed on draining after each step Contaminants left in the compressor after flushing have a direct effect on the fluid s life Once the oxidized material varnish is dissolved in the QuinSyn...

Страница 53: ...ottle 3 Close valve After collecting sample from either of the above methods 1 Fill out information label completely Be certain to provide all information as to possible hazards related to a given sam...

Страница 54: ...s n Sample Values below are in parts per million ppm Date Silver Alum Chrom Copp Iron Nickel Lead Tin Titan Vanad Bari Calc Mag Mol Sod Phos Sili Zinc Fluid Hours Ag Al Cr Cu Fe Ni Pb Sn Ti V Ba Ca Mg...

Страница 55: ...MODEL NUMBER The model number of the Quincy compressor that the fluid sample was taken from i HOURS ON FLUID These are the actual hours that the QuinSyn fluid has been in the unit since the last flui...

Страница 56: ...ion QuinSyn PG 0 40 50 100 QuinSyn XP 0 40 50 100 QuinSyn Plus 0 5 20 20 Phosphorus PPM Plasma Emission QuinSyn PG 0 5 20 20 QuinSynXP 50 5 20 0 QuinSyn Plus 0 5 20 20 Zinc PPM Plasma Emission All 0 1...

Страница 57: ...20 20 Phosphorus PPM Plasma Emission All 0 5 20 20 Zinc PPM Plasma Emission All 0 100 200 200 WEAR METALS Silver PPM Plasma Emission All 0 5 10 10 Aluminum PPM Plasma Emission All 0 5 10 10 Chromium...

Страница 58: ...CORRECT THE SITUATION IN ACCORDANCE WITH THE INSTRUCTION IN THE HIGH DISCHARGE AIR TEMPERATURE SECTION OF THIS TROUBLESHOOTING GUIDE RESTART THE COMPRESSOR CORRECT THE CAUSE OF THE OVERLOADED CONDITI...

Страница 59: ...DISCHARGE AIR TEMPERATURE SECTION OF THIS TROUBLESHOOTING GUIDE RESTART THE COMPRESSOR CORRECT THE CAUSE OF THE MOTOR OVERLOADED CONDITION RESET THE OVERLOAD RELAY AND PRESS THE RESET BUTTON CHECK POW...

Страница 60: ...SURE GAUGE CLEAN AIR FILTER ELEMENT OR REPLACE WITH NEW ELEMENT CHECK SERVICE LINES FOR LEAKS WITH SOAP SUDS REPAIR AS NECESSARY CHECK FOR BUILD UP OR GUMMING OF SHAFT CHECK FLUID FILTER FOR PLUGGING...

Страница 61: ...OES NOT EXCEED MAXIMUM OPERATING PRESSURE CORRECT IN ACCORDANCE WITH INSTRUCTION ON INLET VALVE NOT OPENING OR CLOSING IN RELATION TO AIR DEMAND SECTION OF THIS TROUBLESHOOTING GUIDE CHECK CONTROL SOL...

Страница 62: ...ND DISCHARGE AIR TEMPERATURE DO NOT MIX DIFFERENT GRADES OR TYPES OF FLUID DO NOT MIX FLUIDS FROM DIFFERENT MANUFACTURERS FOLLOW FLUID SPECIFICATIONS AS DESCRIBED IN COMPRESSOR FLUIDS SECTION OF THIS...

Страница 63: ...ING THE RESERVOIR USE FLUID LEVEL GAUGE AS A GUIDE CLEAN SCAVENGER LINE ORIFICE AND TUBE CORRECT IN ACCORDANCE WITH THE INSTRUCTIONS IN HIGH DISCHARGE AIR TEMPERATURE SECTION OF THIS TROUBLESHOOTING G...

Страница 64: ...VALVE ASSEMBLY FAULTY SOLENOID VALVE FAULTY SHUTTLE VALVE LOOSE WIRING CONNECTIONS AT SOLENOID VALVE PRESSURE SWITCH BROKEN SPRING IN AIR INLET VALVE CHECK FOR LEAKS AND CORRECT REPLACE SEAL ASSEMBLY...

Страница 65: ...PILOT VALVE Compressor Will Not Time out Or Shut Down When Unloaded Auto Dual Only FAULTY TIMER LEAKS IN CONTROL LINES LEAKS IN SERVICE LINES FAULTY AIR PRESSURE SWITCH FAULTY AIR PRESSURE SENSORS ADJ...

Страница 66: ...REPLACE AS REQUIRED CHECK OTHER COMPRESSORS ON SAME SYSTEM REPLACE COOLER ADJUST DIFFERENTIAL PRESSURE REGULATOR TO OBTAIN DESIRED MODULATION RANGE READJUST AIR PRESSURE SWITCH SO THAT THE COMPRESSOR...

Страница 67: ...Belt Stretches Beyond Available Take up MISALIGNMENT DEBRIS IN SHEAVES BROKEN TENSILE MEMBER OR CORD DAMAGE MISMATCHED BELTS PROVIDE ADEQUATE GUARDS OR DRIVE PROTECTION FOLLOW CORRECT INSTALLATION PRO...

Страница 68: ...BRATION INCORRECT BELTS SHEAVE OUT OF ROUND LOOSE DRIVE COMPONENTS RETENSION BELTS CLEAN BELTS AND SHEAVES CHECK AUTOMATIC TENSIONING DEVICE INSTALL NEW MATCHED BELT SET DO NOT MIX OLD AND NEW BELTS R...

Страница 69: ...NGES IMPROVE VENTILATION TO DRIVE DO NOT USE BELT DRESSING ELIMINATE SOURCE OF CONTAMINATION Severe or Abnormal Belt Wear WEAR ON TOP OF BELT RUBBING AGAINST GUARD WEAR ON TOP CORNERS OF BELT INCORREC...

Страница 70: ...ID RESERVOIR SERVICE AIR FILTER AS NEEDED DAILY OR WEEKLY IF EXTREMELY DIRTY CONDITIONS EXIST CLEAN AFTERCOOLER AND FLUID COOLER FINS AIR COOLED ONLY WIPE ENTIRE UNIT DOWN TO MAINTAIN APPEARANCE TAKE...

Страница 71: ...Quincy Compressor QSB T 67 THIS PAGE INTENTIONALLY LEFT BLANK...

Страница 72: ...Appendix A Dimensional Drawings 68 Quincy Compressor QSB T QSB 15 50 HP air cooled...

Страница 73: ...Appendix A Dimensional Drawings Quincy Compressor QSB T 69 QSB 15 50 HP water cooled...

Страница 74: ...Appendix A Dimensional Drawings 70 Quincy Compressor QSB T QST 15 50 HP air cooled 120 gallon tank...

Страница 75: ...Appendix A Dimensional Drawings Quincy Compressor QSB T 71 QST 15 50 HP water cooled 120 gallon tank...

Страница 76: ...Appendix A Dimensional Drawings 72 Quincy Compressor QSB T QST 15 50 HP air cooled 200 gallon tank...

Страница 77: ...Appendix A Dimensional Drawings Quincy Compressor QSB T 73 QST 15 50 HP water cooled 200 gallon tank...

Страница 78: ...Heat Rejection Fluid Cooler BTU min 577 563 Aftercooler BTU min 109 91 Aftercooler Approach standard conditions F 8 Maximum Allowable Static Backpressure in H2 O 0 125 Fan Flow cfm 2126 Water cooled C...

Страница 79: ...tercooling Heat Rejection Fluid Cooler BTU min 750 747 725 Aftercooler BTU min 150 129 107 Aftercooler Approach standard conditions F 9 Maximum Allowable Static Backpressure in H2 O 0 125 Fan Flow cfm...

Страница 80: ...Aftercooling Heat Rejection Fluid Cooler BTU min 938 992 974 Aftercooler BTU min 197 181 148 Aftercooler Approach standard conditions F 10 Maximum Allowable Static Backpressure in H2 O 0 125 Fan Flow...

Страница 81: ...ftercooling Heat Rejection Fluid Cooler BTU min 1154 Aftercooler BTU min 210 Aftercooler Approach standard conditions F 18 Maximum Allowable Static Backpressure in H2 O 0 125 Fan Flow cfm 3525 Water c...

Страница 82: ...Aftercooling Heat Rejection Fluid Cooler BTU min 1551 Aftercooler BTU min 281 Aftercooler Approach standard conditions F 18 Maximum Allowable Static Backpressure in H2 O 0 125 Fan Flow cfm 3525 Water...

Страница 83: ...ftercooling Heat Rejection Fluid Cooler BTU min 1983 1987 2001 Aftercooler BTU min 350 Aftercooler Approach standard conditions F 15 Maximum Allowable Static Backpressure in H2 O 0 125 Fan Flow cfm 62...

Страница 84: ..._____________________ ___________________________________________________________________ ___________________________________________________________________ __________________________________________...

Страница 85: ...nt according to percentage of completion Equipment held for Buyer shall be at Buyer s risk and storage charges may be applied at the discretion of Seller Accounts past due shall bare interest at the h...

Страница 86: ...roduct or part thereof must be promptly returned to seller freight prepaid for inspection Seller warrants repaired or replaced parts of its own manufacture against defects in materials and workmanship...

Страница 87: ...o Industries company All Rights Reserved Litho in U S A Quincy Compressor Products 217 222 7700 E mail info quincycompressor com Website www quincycompressor com 314 42nd Street West Williston ND 5880...

Отзывы: