QR-25 Series
Quincy Compressor
52201-105, May 2003
2
3501 Wismann Lane, Quincy IL - 62305-3116
•Do not remove or paint over any DANGER!, WARNING!, CAUTION!, or
instructional materials attached to the compressor. Lack of information
regarding hazardous conditions can cause property damage or personal injury.
•Periodically check all pressure relief valves for proper operation.
•Do not rebuild or change the pressure setting of the pressure relief valve,
restrict the function of the inlet or outlet of the pressure relief valve, or replace
the pressure relief valve with a plug or any device not specifically certified for
this function.
•Do not install a shutoff valve in the compressor discharge line without first
installing a pressure relief valve of proper size and design between the shutoff
valve and the compressor.
•Do not use plastic pipe, rubber hose, or lead-tin soldered joints in any part of
the compressed air system.
•Alterations must not be made to this compressor without Quincy Compressor’s
approval.
•Be sure that all tools, shipping and installation debris have been removed
from the compressor and installation site prior to starting the compressor.
Do not operate a Quincy Compressor in excess of 250 PSIG unless it
has been tested and certified for high pressure application by
Quincy Compressor prior to shipment.
•High pressure units (pressures exceeding 250 PSIG) require parts certified
for use in high pressure applications. When replacing parts on high pressure
units, please consult the parts manual and use only the part numbers listed in
that manual.
•Do not operate the compressor in excess of the ASME pressure vessel rating
for the receiver or the service rating of the compressor, whichever is lower.
•Make a general overall inspection of the unit daily and correct any unsafe
situations.
•Reckless behaviour of any kind involving compressed air is dangerous and
can cause very serious injury to the participants.
•Provisions should be made to have the instruction manual readily available
to the operator and maintenance personnel. If for any reason any part of the
manual becomes illegible or the manual is lost, have it replaced immediately.
The instruction manual should be read periodically to refresh one’s memory.
It may prevent a serious or fatal accident.
•Never use a flammable or toxic solvent for cleaning the air filter or any parts.