QR-25 Series
Quincy Compressor
52201-105, May 2003
25
3501 Wismann Lane, Quincy IL - 62305-3116
Pix 1153
Fig. 5-2
Belt Tension Gauge
*Full load amps (FLA) & Service Factor can usually be found on the motor nameplate.
Pix 1067
Fig. 5-3 Pressure Switch
PRESSURE
ADJUSTMENT
SCREW
ELECTRICAL
CONTACTS
Pressure Switch Adjustment
Pressure switches provided by Quincy Compres-
sor are pre-set at the factory and usually do not
require adjustment. However, the following pro-
cedures can be performed by a qualified electri-
cian to adjust the pressure switch.
Step 1)
Remove the pressure switch cover.
Step 2)
While the compressor is running, screw
the spring loaded adjustment screw in (clockwise)
to increase the amount of air pressure required to
open the switch and stop the unit. Screw the
spring loaded adjustment screw out (counterclock-
wise) to decrease the amount of air pressure re-
quired to open the switch and stop the unit.
Standard pressure switches supplied by Quincy
Compressor are equipped with a fixed 20 p.s.i.g.
(approx.) differential. Optional switches include
both pressure and differential adjustment capabili-
ties.
Electric power always exists inside the pressure switch whenever
the compressor package is connected to a power supply. Be careful
not to touch any electrical leads when setting the pressure switch.
Never exceed the designed pressure for the system or overload the
motor beyond its Maximum Amp Draw.
* Full Load Amps x Service Factor = Maximum Amp Draw
Never assume a compressor is safe to work on just because it is not
operating. It may be in the automatic stand-by mode and may
restart any time. Follow all safety precautions outlined in SEC-
TION 5,
Stopping For Maintenance.
WARNING !
WARNING !
WARNING !