QR-25 Series
Quincy Compressor
52201-105, May 2003
30
3501 Wismann Lane, Quincy IL - 62305-3116
Trouble
Probable Cause
Intercooler pressure
•Compressor valves or valve unloaders in first stage not functioning
abnormally low
properly or defective
(Two stage models only)
•Restricted air inlet filter or suction line
•Pilot valve or pressure switch set incorrectly or defective
•Pressurized air at valve unloader not venting properly when demand for
air is required; vent passage at hydraulic unloader or three-way valve
could be plugged
•Compressor valve or head gasket leaking
•Worn piston rings
•Defective pressure gauge
•Leaking air at intercooler or intercooler connections
Compressor overheats
•Clogged intake system
•Defective compressor valves
•Pressure setting too high
•Clogged intercooler, internally or externally
•Clogged water passages in cylinder head &/or cylinders
•Defective water temperature regulator valve
•Inadequate cooling water flow, ventilation, or recirculation of hot air
•Pulley/sheave rotation wrong
•Incorrect speed
•Running clearances insufficient
(piston to cylinder wall or running gear)
•Lubrication inadequate
•Compressor incorrectly sized
High discharge
•Defective water temperature regulating valve
temperature
•Inadequate cooling water flow
•Compressor valve assemblies defective
•Discharge pressure too high
•Inadequate ventilation or hot air recirculating
•Cooling surfaces of compressor or intercooler excessively dirty
•Internal surface of heat exchanger fouled
•Ambient temperature too high
•Scored or excessively worn cylinder walls
•Cooling water temperature too hot
Compressor knocks
•Head clearance insufficient
•Piston loose in cylinder bore, cylinder bore worn, piston or piston rings
worn
•Worn rods or main bearing
•Wrong pressure setting, discharge pressure excessive
•Crankcase lubrication inadequate
•Loose pulley/sheave
•Compressor valve assemblies loose
Содержание QR-25 Series
Страница 42: ......