3.29 Calling up/modifying high ambient temperature setting
Calling up/modifying high ambient temperature setting
In protection parameter set Pr. 3, the
High ambient temperature alarm level
(<AL-H>) and the
High ambient
temperature shutdown level
(<Sd-H>) can be set. Both values are adjustable between 35 °C (95 °F) and 60
°C (140 °F).
Starting from the Main screen, press Scroll button (12) until <Pr. 3> is shown and then press Enter button
(13): <AL-H> is shown.
Press Enter button (13): the programmed value starts blinking. Use the Scroll buttons (12) to modify.
Press Enter button (13) to confirm the new value and press Escape button (12) to return to previous screen.
From the screen where <AL-H> is shown, use the Scroll buttons (12) to go to <Sd-H>.
The value of <Sd-H> can be modified in a similar way.