Residential Gas Hydronic Heating System
Residential Gas Hydronic Heating System
Residential Gas Hydronic Heating System
Residential Gas Hydronic Heating System
QVM 9
Series
20
20
20
20
Installation of the Flue
Installation of the Flue
Installation of the Flue
Installation of the Flue
Schematic of SCF-9 Installation
Schematic of SCF-9 Installation
Schematic of SCF-9 Installation
Schematic of SCF-9 Installation
Install the flue ensuring that it
cannot be blocked by snow falling
from the eaves.
Install the flue in a location where no
opening exists within 20" from the flue
so that exhaust gas cannot recirculate
into the building.
Install the flue in a place where
there are no obstacles within 5
ft from the flue end.
Seal so as not to let the
exhaust waste gas leak
into the room.
In the event the intake hose is
too long, cut to the shortest
length as possible and
connect
it to the boiler.
Install the flue at least 2ft above the
ground. Ensure it cannot become
blocked by snow fall deposits.
10
”
or
more
25
”
or
more
6
”
or more
Nonflammable
Wall
Ceiling