OPERATION MANUAL
Page 8
T0 is the valve temperature for bottom heater required by top heater when it heats up. Also it is the first
temperature of this technics process. When the work flow begins, the bottom heater starts to heat up. After
reaching the T0, the top heater begins to heat up.
TB, Tb, TC
TB: The setting temperature of bottom preheating Tb: Real-time temperature of bottom heating TC:
Real-time temperature of top heating
T1
It is the heat preservation starting temperature of reflow soldering. It is the second temperature of this
technics process. The temperature rises to T1 with a proper speed the component permits. In parameter
modifying, use the “
↑
” and “
↓
” key to set the value of T1.
T2
It is the temperature when finish the heat preservation of reflow soldering. The pre-heating temperature rises
to T2, after the time of S1 finishes. Within this time, PCB and component pre-heating is finished and the
solder is activated. In parameter modifying, use the “
↑
” and “
↓
” key to set the value of T2.
T3
It is the peak value temperature of reflow soldering. When the temperature reaches T2, the temperature
equably rises to T3 with a definite raising speed. The soldering or de-soldering will be finished when the
temperature reaches to the peak value and performs the next step. In parameter modifying, use the “
↑
” and
“
↓
” key to set the value of T3.
TL
Melting temperature of solder. At this temperature, the solder starts to melt down and turn into liquid.
During the soldering and de-soldering, users can press “CALTL” Key to calibrate the value of TL when the
solder turn into liquid. In parameter modifying, use the “
↑
” and “
↓
” key to set the value of TL.
S1
Heating time rising from T1 to T2. User can set the value in the range of 0~300s.
S2
Heating time rising from T2 to T3. User can set the value in the range of 0~300s.
S3
Prolonged heating time (Heat preservation time) after the temperature reach T3, and user can also set the
value in the range of 0~300s.
Unit
It’s able to set the unit of display temperature during work flow. In parameter modifying, use “
↑
” and “
↓
”
keys to set the value of it.
Sense
It is used for choosing the system’s sensor type. Users can also choose K type sensor used for measuring
temperature, besides system’s IR sensor. The signal of chosen sensor will be displayed and used for process