background image

Thank you for purchasing the Hakko 850D SMD Rework
Station. This unit features digital control and display of hot
air temperature.
Please read this manual before operating the Hakko 850D.
Keep this manual readily accessible for reference.

®

SMD Rework Station

TABLE OF CONTENTS

PACKING LIST / SP ECIFICATIONS ..................................................... 1

SAFETY INSTRUCTIONS .................................................................... 2

PART NAMES ....................................................................................... 3

PREPARATION: ASSEMBLY AND ELECTRICAL CONNECTION ....... 4

OPERATION ......................................................................................... 5

PARAMETERS / INITIAL RESETTING ................................................ 7

USE ...................................................................................................... 8

MAINTENANCE / INSPECTION ........................................................ 10

ERROR MESSAGES ......................................................................... 11

TROUBLESHOOTING ....................................................................... 12

OPTIONAL NOZZLE .......................................................................... 13

PARTS LIST / STATION ...................................................................... 15

HANDPIECE ................................................................ 17

WIRING DIAGRAM ............................................................................ 18

Содержание 850D

Страница 1: ...Keep this manual readily accessible for reference SMD Rework Station TABLE OF CONTENTS PACKING LIST SPECIFICATIONS 1 SAFETY INSTRUCTIONS 2 PART NAMES 3 PREPARATION ASSEMBLY AND ELECTRICAL CONNECTION...

Страница 2: ...7 9 in 200 g 0 44 lb Handpiece This product is ESD protected Specifications and design subject to change without notice PACKING LIST Hakko 850D station 1 Handpiece holder 1 Control card 1 Card chain...

Страница 3: ...personnel or touch the metal parts near the nozzle Do not use the product near combustible gases or flammable materials Advise those in the work area that the unit can reach very high temperatures and...

Страница 4: ...crew Heater indicator lamp Jack for optional foot switch Handpiece holder Fuse Nozzle not included This jack is for the foot switch only Do not connect any other device S CAUTION 4 5 AIR CONTROL 3 2 1...

Страница 5: ...h the nozzle Loosen the nozzle mounting screw Attach the nozzle as shown in the drawing Figure 2 C Electrical Connection and Power ON 1 Place the handpiece on the holder Figure 4 2 Plug the power cord...

Страница 6: ...initiated by the second activation of the Start switch CAUTION Do not stop the hot air by turning the power switch OFF CAUTION To avoid damage to the equipment do not turn the power switch OFF until...

Страница 7: ...digit flashes on the display indicating that the HUNDREDS digit can be entered NOTE It can be flashing even though no card in the unit but the temperature cannot be set 3 Enter the HUNDREDS digit Use...

Страница 8: ...or F temperature display selection 2 Power save time select 30 or 60 minutes 3 Sensor temperature display Once the station enters parameter mode set the parameters in the order shown below After all...

Страница 9: ...the photo shown If the width of the IC does not match the size of the FP pick up adjust the width of the pick up by squeezing the wire In case of PLCC or small components such as chip resistors desold...

Страница 10: ...ring is completed clean the residual flux from the board with an appropriate cleaner NOTE Soldering with hot air has many advantages such as the inherent ability to pre heat the component being replac...

Страница 11: ...ion are inside the pipe Be careful not to drop or lose these items 4 Disconnect the heater sensor connector and remove the heater 2 Measure the resistance value 1 Measure the resistance value a of the...

Страница 12: ...r procedures to correct the error Sensor Error This error occurs when there is the possibility of a sensor failure or a failure in the sensor circuit flashes and the power is shut down Heater Error Th...

Страница 13: ...the fuse blown ACTION Investigate why the fuse blew and then replace the fuse If the cause can not be determined replace the fuse If the fuse blows again send the unit in for repair flashes indicatin...

Страница 14: ...0 3 x 0 7 7 2 0 28 19 0 75 A1135B PLCC 17 5 x 17 5 0 68 x 0 68 44 Pins 15 0 59 15 0 59 A 18 5 0 73 B 18 5 0 73 A1136B PLCC 20 x 20 0 78 x 0 78 52 Pins A1137B PLCC 25 x 25 0 98 x 0 98 68 Pins A1138B P...

Страница 15: ...1 39 B 35 2 1 39 A 42 5 1 67 B 42 5 1 67 A1257B SOP 11 x 21 0 43 x 0 83 21 0 83 A1259B SOP 13 x 28 0 51 x 1 1 13 5 0 53 A1260B SOP 8 6 x 18 0 34 x 0 71 8 7 0 34 19 0 75 29 1 14 A1258B SOP 7 6 x 12 7 0...

Страница 16: ...er foot Description 120 V 100 120 V 110 120 V With high nut nylon band double side tape 8 x 5 x 130 mm 0 3 x 0 2 x 5 1 in With silicone tube assembly 4 ea Item No 1 Part No B1649 Part Name Foot switch...

Страница 17: ...M2 6 x 10 2 Tapping screw Fluted point M2 6 x 6 3 Item No 1 2 3 4 5 6 7 8 9 10 Part No B2452 A1434 B2735 B2456 B2457 B2458 B1354 B2736 B2635 B2634 Part Name Pipe Heating element Handle Packing Termin...

Страница 18: ...cord Fuse Transformer Handpiece Terminal board CA sensor Heater Heater element 1 GND 1 1 1 1 3 CN10 1 CN2 Jack for foot switch 2 P W B Display CN4 3 1 3 12 CN3 1 11 1 CN9 CN8 CN6 P W B Heat control CN...