BGA2015 OPERATION MANUAL
Page7
Note:
Adjusting the aperture system can protect the adjacent components on the PCB from being
heated. But, when the aperture system is adjusted to small size, the Top Radiator will be very
hot and decrease its lifetime, so it’s necessary to increase the window size appropriately to
avoid the damage of the Top Radiator.
8.2 Parameters Setting
Parameter settings order as the follows:
A
.
_password: ***
(
Password settings
)
B
、
_select: 0
(
Flow settings, it can modify parameter inside.
)
C
.
_type: solder
(
Working mode settings
)
D
.
_laser: off
(Laser alignment settings)
E
.
_baud: 19200
(
Communication speed settings
)
A. Input password
The initial password of system is “000”. At the same time, system also has the omnipotent
password “159”. If you forget the setting password, you can input “159” to make the password
of system come back to initial password “000”.
Note:
If want to modify any parameter system, you must input password, otherwise, you can only
browse them.
For instance: Input the initial password “000” of system.
press
MENU press MENU
TC:022˙C Tb:019˙C
ready for flow
_password: ***
select: 0