BGA2015 OPERATION MANUAL
Page3
components.
Note: Top and bottom IR radiator will be very hot during working, so explosive and
combustible object or gas and solvent is strictly prohibited in working areas, also please
don’ touch the hot housing parts
Note: The laser alignment device includes two secondary laser device, so don’t see the laser
bean directly.
Note: When the system happens trouble and needs maintenance, it should be carried on by a
experienced and authorized technician or expert, or contact with service agent and
factory.
The unit with dangerous voltage! The inexperienced work is dangerous for operators.
5. Specifications and Technical Parameters
5.1
Specifications
1
.
Total power: 2400W
(
max
)
2
.
Power of Bottom Heater: 400W*4=1600W
(
Infrared ceramic heating tube
)
3
.
Power of Top Heater: 120W*6=720W
(
Infrared heating tube,
wavelength about 2~8µm
,
size:60*60mm
)
4
.
Preheating Time of Bottom Heater: about:90s, size:260*260mm
5
.
Top heater range size: 20~60mm
6
.
Heating time of Top Heater: about 10s
(
room temperature~230
℃)
7
.
Vacuum Pump: 12V/300mA, 0.05Mpa
8
.
Top cooling Fan: 24V/300mA 00CFM
9
.
Laser Alignment Tube: 5V/30mA 2pcs
10
.
LCD Display window: 65.7*23.5
(
mm
)
16*2 character
11
.
Communication: Standard USB connector (Connect with PC
)
12
.
Movable Motor : stepping motor
13
.
Movable Arm Range: 128mm
14
.
Infrared Temperature sensor : 0~300
℃(
Testing range
)
00
.
Outside K Type Sensor: 3pcs
16
.
Max PCB Size : 400mm*400mm
17
.
fuse 3pcs, 20A
(
220V
)