b) Activation of Programming Level B
Deactivate key T9 (P/M) (going dark) and activate key T10 (T/E) (going bright).
Response:
In the righthand half of the display are shown: a parameter number (at first 105, then the number
selected last) and the associated value.
Sewing is not possible.
Modification of
parameter number
:
for hundreds of parameter numbers use key P+ or P-
for tens and units of parameter numbers use key S+ or S-
Modification of
parameter value
: via key L+ or L-
c) Deactivation of Programming Level B
Deactivate key T10 (T/E) (going dark)
Response:
Parameters shown disappear from the display, the display returns to initial condition
Sewing is possible.
9.1.2.3 Programming Level C (Special Level)
At this level, control parameters are stored the values of which have to be modified in exceptional cases
only. Correction of these parameters should therefore be made only after consultation of the
manufacturer.
a) Activation of Programming Level C
- Activate programming level B (see 9.1.2.2)
- Call up parameter 798
- Set parameter value <798> to I
- Deactivate programming level B
- Turn mains power switch OFF, wait for >2 secs. to elapse
- Turn mains power switch back ON
- Deactivate key T9 (P/M) (going dark)
- Activate key T10 (T/E) (going bright)
Q-41-MSII-2-EN
9.5
02-02-21
1 0 1 0 1 0 5 1 500
1 0 1 0 x x
4
00