17
ID
FAQ
Answer
1
What happens if
units are powered
up for the first time
but no buttons are
pressed?
Units will search for a network for 15 minutes
after which all units will go into Standby and the
LEDs will be turned off.
To retry, press the RF button twice quickly to
re-enter Join Mode. See Section 7.1 for details.
2
What happens if a
Peer doesn’t find
a network during
the joining process
(eg. due to defective
radio link, being out
of range, or couldn’t
find a Host)
Unit will go into standby and Amber LED will
flash every 2 seconds indicating Network not
found. The unit will then become a stand alone
smoke alarm with no interconnect.
3
What happens if a
Host doesn’t find
any Peer to join after
being set as Host.
Host times out after 15 min, becomes a stand
alone smoke alarm with no interlink.
Peer times out after 15 minutes, becomes a
stand alone smoke alarm.
Amber LED will flash every 2 seconds indicating
that they are not joined.
4
What happens if an
Peer drops from the
network?
The Peer will enter fault mode after
approximately 30min.
5
What happens if an
Peer drops from the
network and comes
back online?
Nothing within ~30min.
After 30 minutes it will go into error mode -
network fault. Once the Peer comes back online,
pressing the RF button twice on any unit in the
network will allow it to re-join.
6
What happens if the
Hos t drops from
the network?
IF no other units can hear the Host AND Peer1
can hear all the others: Peer unit 1 becomes
the Host after 30 min and other Peer's will
re-join.
8. Wireless FAQs