15
At some point, you might want to add another smoke alarm unit to your
existing RF interlink network for additional protection, or to replace an old
unit. Follow the steps in the following table.
7.2 Adding A Smoke Alarm To An Existing RF Interlink Network
User Input
Detector
Response
Timeout
Step 1
Press the RF
button twice on
any existing unit.
Unit will respond with
two quick flashes every 2
seconds if it is the Host of
the Network; three quick
flashes every 2 seconds
if it is an Peer in the
Network - Join Mode is
open.
Join Mode will
timeout in 15
minutes
Step 2
Power up unit(s)
to be added - by
mounting the
smoke alarm onto
the baseplate
mounted by an
Electrician.
For previous units
that have been
reset, press the
RF button twice to
enter Join Mode.
Amber LED flashes three
times every 2 seconds to
indicate it is configured
(as a Peer) in the network
Join Mode will
timeout in 15
minutes
Step 3
After new unit(s)
have joined, press
RF button twice
on any unit in the
network to close
Join Mode.
Amber LED on each unit
will power off indicating
Standby Mode
Join Mode will
timeout in 15
minutes
Step 4
Test to verify
interconnect
operation.