5. Installation
!
Note: Use approved listed Australian Standards cable 1.0mm² TPS
or larger as required by local codes.
FIGURE 3 “INTERCONNECT WIRING DIAGRAM”
A
(Active Side of
AC Line)
(Neutral side of
AC Line)
I/C
(Intercon-
nection Line)
N
FUSE OR CIRCUIT BREAKER
Figure 3
NOTE : AC power should be turned off at this stage.
Caution! Turn off the main power to the circuit before wiring
the alarm.
• Select a suitable alarm location as per the guidance in
Pages 4
and 5
• For surface mount cable applications where the cable is housed in a
suitably approved surface mount cable duct:
1. Install the duct to terminate at the side of the alarm base.
2. Remove a ‘knock out’ / ‘cable access’ on one side of the alarm
base. There is one on each side of the base. (refer to Figures 4A)
3. Position the duct to the alarm base, so the channel in the base
aligns with the duct.
4. The cable can transition from the duct to the base.
5. It may be necessary to remove the outer sheath prior to securing
the base to the ceiling. (Excess cable may restrict the terminal cover
from securing shut).
6. Terminate the cables in the terminals provided to meet with relevant
local code requirements. Insert the cables into the terminals
clamping the terminal to the copper by tightening the screw on
each terminal.
7. Secure the alarm base to the surface with the fixings provided.
(refer to Figures 4D).