LTE Module Series
EC25&EC21 AT Commands Manual
EC25&EC21_AT_Commands_Manual 206 / 231
Parameter
13.4. AT+QADC Read ADC Value
The command is used to read the voltage value of ADC channel.
Parameter
OK
If there is any error related to ME functionality:
+CME ERROR: <err>
Maximum Response Time
300ms
Reference
3GPP TS 27.007
<bcs>
Battery charge status
0
ME is not charging
1
ME is charging
2
Charging has been finished
<bcl>
Battery charge level
0-100
Battery has 0-100 percent of capacity remaining vent
<voltage>
Battery voltage (Mv)
AT+QADC Read ADC Value
Test Command
AT+QADC=?
Response
+QADC: (0,1)
OK
Read Command
AT+QADC=<port>
Response
+QADC: <status>,<value>
OK
Maximum Response Time
300ms
<port>
Channel number of the ADC
0 ADC Channel 0
1 ADC Channel 1
<status>
Indicate whether the ADC value is read successfully