LTE Module Series
EC25&EC21 AT Commands Manual
EC25&EC21_AT_Commands_Manual 19 / 231
2.12. AT&W Store Current Parameters to User Defined Profile
The command stores the current AT command settings to a user defined profile in non-volatile memory.
Parameter
2.13. ATZ Set all Current Parameters to User Defined Profile
The command restores the current AT command settings to the user defined profile in non-volatile
memory, if one was stored with
AT&W
before. Any additional AT command on the same command line
may be ignored.
Parameter
AT&W Store Current Parameters to User Defined Profile
Execution Command
AT&W[<n>]
Response
TA stores the current parameter settings in the user defined
profile. See
Table 9
.
OK
Maximum Response Time
300ms
Reference
V.25ter
<n>
0
Profile number to store current parameters
ATZ Set all Current Parameters to User Defined Profile
Execution Command
ATZ[<value>]
Response
TA sets all current parameters to the user defined profile. See
Table 10
.
OK
Maximum Response Time
300ms
Reference
V.25ter
<value>
0
Reset to profile number 0