LTE Module Series
EC25&EC21 AT Commands Manual
EC25&EC21_AT_Commands_Manual 26 / 231
2.22. AT+CFUN
Set Phone Functionality
The command controls the functionality level. It can also be used to reset the UE.
Parameter
Example
AT+CFUN=0
//Switch phone to minimum functionality
OK
AT+COPS?
+COPS: 0
//No operator is registered
OK
AT+CPIN?
AT+CFUN Set Phone Functionality
Test Command
AT+CFUN=?
Response
+CFUN:
(list of supported
<fun>
s)
,
(list of supported
<rst>
s)
OK
Read Command
AT+CFUN?
Response
+CFUN: <fun>
OK
Write Command
AT+CFUN=<fun>[,<rst>]
Response
OK
If there is any error related to ME functionality:
+CME ERROR: <err>
Maximum Response Time
15s, determined by network.
Reference
3GPP TS 27.007
<fun>
0
Minimum functionality
1
Full functionality (Default)
4
Disable the ME from both transmitting and receiving RF signals
<rst>
0
Do not reset the ME before setting it to
<fun>
functionality level.
This is the default setting when
<rst>
is not given.
1 Reset the ME. The device is fully functional after the reset. This value is available
only for
<fun>