9. Electrical Diagram (12-24 Vdc)
Notes for diagram:
+
+Vdc (12-24 Vdc)
-
-Vdc (0 Vdc)
Q1
⬆
Output for motor UP (open)
Q2
⬆
Output for motor DOWN (close)
I2
Input for switch/push button DOWN (close)
I1
Input for switch/push button UP (open)
TS
Temperature sensor terminal
S
Service button (used to add or remove device from the Z-Wave network)
Overload
Max Power Limit is automatically set by a software. If max power aprox. 60W is exceeded for
more than 5 seconds, the output is turned off up to next power cycle of the module. When
overload occurred, Event “Over
-
load detected” is sent to the gateway
.