![QUBINO FLUSH SHUTTER DC Скачать руководство пользователя страница 38](http://html1.mh-extra.com/html/qubino/flush-shutter-dc/flush-shutter-dc_user-manual_3593005038.webp)
EN
.
38
•
Group 6: Basic on/off (triggered at reaching roller position: bottom=FF, not bottom=0) up
to 16 nodes
When blinds reach down position, Flush Shutter DC will send Basic set ON command and
the device will turn ON. When blinds are in any position which is not down (0 %) Flush
Shutter DC will send Basic set OFF to associated device and the device will turn OFF.
•
Group 7: Multilevel set (Triggered at change of value of the Flush Shutter DC position), up
to 16 nodes.
Flush shutter DC will set Switch multilevel command to associated device, the command
is actual position of blinds so the associated device will turn on same level as blinds are.
Example with association between Flush Shutter DC and dimmer, when shutters blinds
reach middle position 50% it will send switch multilevel set 50 % command and dimmer
will turn on 50 %.
•
Group 8: Multilevel set (Triggered at changes of value of slats tilting position), up to 16
nodes. Flush Shutter DC device will send Switch multilevel set command to associated
device, the command is actual position of tilts.
Example with association between Flush shutter DC and dimmer
When shutters tilts rotate to middle position 50% it will send switch multilevel set 50 %
command and dimmer will turn on 50 %.
•
Group 9: Multilevel sensor report (triggered at sensed different value
–
sensor sold
separately), up to 16 nodes. Flush Shutter DC device will send Multilevel sensor report to
associated device, this will send the information of actual temperature that was
measured with temperature sensor.
End point 1:
•
Group 1: Lifeline group, 0 nodes allowed.
•
Group 2: Basic on/off (Triggered at change of input I1) up to 16 nodes.
When switch wired to input I1 is pressed Flush Shutter DC will send Basic set ON command
to associated device and this device will turn ON, when it is released Flush shutter DC
sends Basic set OFF command to associated device and this device will turn OFF.
•
Group 3: Basic on/off (Triggered at change of input I2) up to 16 nodes.
When switch wired to input I2 is pressed Flush Shutter DC will send Basic set ON command
to associated device and this device will turn ON, when it is released Flush shutter DC
sends Basic set OFF command to associated device and this device will turn OFF.
Содержание FLUSH SHUTTER DC
Страница 3: ...EN 3 18 Warning 58 19 Regulations 58...
Страница 16: ...EN 16 4 Package Contents Flush Shutter DC Device Installation Manual...
Страница 23: ...EN 23 After Qubino installation...
Страница 29: ...EN 29 Step 2 Turn the fuse OFF Step 3 Connect the temperature sensor as shown below...
Страница 30: ...EN 30 Step 4 Place the temperature sensor in the switch box Step 5 Turn the fuse ON...
Страница 31: ...EN 31 Step 6 Re include the device to your network...
Страница 32: ...EN 32 Step 7 Start using the temperature sensor in connection with your device...