15. Technical Specifications
Power supply
12-24 Vdc +/-10 %
Rated load current
2 A
Overcurrent protection
5 A
Output circuit power of DC output
(resistive load)
48 W (24 Vdc)
Power measurement accuracy
+/-5 %
Digital temperature sensor range
-25 ~ +80
°C (
-13~ 176
°F),
resolution 0.1
°C
Operation temperature
-10 ~ +40
°C (14 ~ 104
°F)
Z-Wave operation range
up to 40 m indoors (131 ft)
Dimensions (WxHxD) (package)
41,8x36,8x16,9 mm (86x74x43 mm) / 1,65x1,45x0,66 in
(3,39x2,91x1,69 in)
Weight (with package)
28g (54g) / 0.99oz (1.90oz)
Electricity consumption
0,4 W
For installation in boxes
Ø ≥ 60 mm (2,36 in)
or 2M
Switching
H bridge
Z-Wave Repeater
Yes
Protection degree
IP20