6) By default full turn movement is set to 1.5s. If this time is too long (if after slates full cycle
Shutter starts moving up or down), decrease this time defined with parameter 72. If this time is
to short (if slats will not turn for a full cycle), increase this time defined with parameter 72.
Manual operation for Shutter
(par. 71 set to 0)
The user can connect a push-button (mono-stable) or a switch (bi-stable) to I1 and I2 terminals.
Pressing the push-button for less than 2 seconds, which is connected to I1 (up), initiates up
movement.
Pressing the push-button for less than 2 seconds, which is connected to I2 (down), initiates down
movement.
If the Shutter is moving, any press (of any push-button) will stop the movement.
Keeping the push-button, connected to I1 (up), pressed for more than 2 seconds initiates up
movement, until the push-button is released.
Keeping the push-button, connected to I2 (down), pressed for more than 2 seconds, initiates
down movement, until the push-button is released.
Manual operation for venetian blinds
(par. 71 set to 1)
Slates on start position - 0 degree
Clicking the push-button connected to I1 (up), initiates shutter up movement, until push-button
is clicked again.
Clicking the push-button connected to I2 (down), initiates Shutter down movement.
If the Shutter is moving, any click (of any push-button), will stop the movement.
Keeping the push-button pressed (for time > full turn slates time-par.72) connected to I1 (up),
initiates full slates turn and up movement, until the push-button is released.
Keeping the push-button pressed (for time > full turn slates time-par.72) connected to I2 (down),
initiates Shutter down movement, until the push-button is released.
Содержание FLUSH SHUTTER DC
Страница 3: ...EN 3 18 Warning 58 19 Regulations 58...
Страница 16: ...EN 16 4 Package Contents Flush Shutter DC Device Installation Manual...
Страница 23: ...EN 23 After Qubino installation...
Страница 29: ...EN 29 Step 2 Turn the fuse OFF Step 3 Connect the temperature sensor as shown below...
Страница 30: ...EN 30 Step 4 Place the temperature sensor in the switch box Step 5 Turn the fuse ON...
Страница 31: ...EN 31 Step 6 Re include the device to your network...
Страница 32: ...EN 32 Step 7 Start using the temperature sensor in connection with your device...