QF5050SU; edition 2016-05; page 3 of 18   

 

1. General 

 

1.1. Introduction 

 
These operating instructions are valid for the Quattroflow 5050SU pump. 
 
No liability will be undertaken for any damages caused by non-compliance with the operating 
instructions and service conditions! Original spare parts serve safety purposes. The use of other parts 
may cancel the liability for the consequences and secondary failures resulting thereof.  
 
Manufacturer:  ALMATEC Maschinenbau GmbH  

  

Carl-Friedrich-Gauss-Str. 5 
47475 Kamp-Lintfort, Germany 
Phone: +49 2842 961-0 

  

 

Fax: +49 2842 961-40 
e-mail: [email protected] 

  

 

Internet: www.quattroflow.com 

 
Quattroflow quaternary diaphragm pumps are constructed according to the state of the art and they 
are reliable. Imminent danger by operating error or misuse can lead to damages of properties and/or 
persons. The pumps are to be applied for the intended use and in a safety-related proper condition 
only. 
 

1.2. Storage 

 
In general the Quattroflow pump is delivered operational and packaged. If the unit is not installed right 
away, proper storage conditions are important for a trouble free operation later. The pump has to be 
protected from wetness, coldness, dirtying, UV-radiation and mechanical influences. The following 
storage conditions are recommended: 
- Steady ventilated, dust and vibration free storage room 
- Ambient temperature between 15°C (59°F) and 25°C (77°F) with a relative humidity below 65% 
- Prevention of direct thermal influences (sun, heating) 
 

1.3. Labelling of the pump 

 
The ALMATEC Maschinenbau GmbH is certified as a modern, quality-orientated enterprise according 
to DIN EN ISO 9001:2008 and 14001:2009. Before release for dispatch, any Quattroflow pump has to 
undergo an extended final control. The performance data registered during this are archived in our 
records and can be read back at any time. 
 
As a general rule in the countries of the EU only such machines are allowed to take into operation, 
which are determined to meet the regulations of the EU machinery directive, the harmonized 
standards, European standards and the respective national standards. Hence the operator has to 
verify whether the Quattroflow pump manufactured and delivered properly according to the customers 
order meets the mentioned requirements.  
 
Therefore make sure, before putting the pump into operation, that the pump and the used materials of 
construction are suitable for the provided application and the installation site. 
 
Each Quattroflow 5050SU pump has a type label. Besides, the serial number is fixed at the front 
cover. 

Содержание 5050SU

Страница 1: ...aternary Pump With Polypropylene Pump Chamber Single Use Please read this manual carefully before start up of the pump and take care of an appropriate instruction of the operating staff Attention Plea...

Страница 2: ...structions 7 3 5 Safety hints for the operator 7 3 6 Safety instructions for maintenance inspection and mounting operations 8 3 7 Unauthorized reconstruction and spare part usage 8 3 8 Inadmissible mo...

Страница 3: ...dness dirtying UV radiation and mechanical influences The following storage conditions are recommended Steady ventilated dust and vibration free storage room Ambient temperature between 15 C 59 F and...

Страница 4: ...dges or plate and frame depth filters Chromatography Packing of chromatography columns Feed pump to mix gradients Feed pump for centrifuges or separators Feed pump for homogenizers Feed pump for filli...

Страница 5: ...ck with appropriate analytical methods the success of the flushing procedure Recommendation Test run prior first use Before using your pump in your process perform a test run to get used to the specif...

Страница 6: ...ump chamber in a vacuum autoclave at max 130 C 266 F for max 30 min Follow instructions of the autoclave manufacturer 4 After cooling down the screws of the membrane housing cover and the connectors s...

Страница 7: ...the safety guidelines of this manual as well as all national and possible internal regulations e g the handling of chemicals like caustic or acid the handling of biological materials the handling of...

Страница 8: ...tart up and check the tightness of the pump o Please respect the relevant additional security advices if the pump has been used for aggressive dangerous or toxic liquids e g suitable protective equipm...

Страница 9: ...y case if the pump will be the right tool for the specific application The user operator is responsible to perform a proper method of testing if the pump should be applied for his specific application...

Страница 10: ...box or the motor is to be opened only by skilled personnel Check the electrical cables before connecting to mains supply During all maintenance work it has to be ensured that no explosive atmosphere c...

Страница 11: ...verified For corrosion reasons or a clearly audible operating noise the parts of the bearing service kit should be also replaced PSKITWLC44 Tension roller Q531053020 and drive belt Q6158 419 with wea...

Страница 12: ...idation is inapplicable The replacement of the pump chamber can be conducted by the operator Please follow the drawings for the disassembly and assembly Before starting the disassembly ensure that the...

Страница 13: ...sider the following tightening torques during the installation of the pump chamber Picture 1 Step 3 Fastening screws 25 Nm 18 4 lb ft Picture 3 Step 1 Clamp ring screw 5 Nm 3 7 lb ft 1 Push SU pump ch...

Страница 14: ...Tension roller Q531053020 Drive belt Q6158 419 The replacement of the bearing unit can be conducted by the operator The following drawings describe it step by step 7 For mounting the pump chamber to...

Страница 15: ...e liquid to be pumped 8 X X Check pressure head open valve in discharge line completely remove obstruction in discharge line 9 X Pressure line completely or partly clogged diaphragm maybe broken chang...

Страница 16: ...If translation is used Pump rpm motor rpm x reduction ratio 0 10 20 30 40 50 60 70 80 90 100 0 500 1000 1500 2000 2500 3000 3500 4000 4500 5000 5500 6000 0 200 400 600 800 1000 1200 Flow rate L min F...

Страница 17: ...e approx cm inch 1669 259 Speed range pump rpm 1 1285 Connection specification inlet standard Connector 1 5 TC Flange diameter mm inch 50 5 Internal diameter mm inch 34 Connection specification outlet...

Страница 18: ...x height mm inch 234 x 105 x 314 9 21 x 4 13 x 12 36 Weight approx kg lb 8 17 64 All technical data relate to a Quattroflow pump in the standard version Special designed pumps e g special product conn...

Отзывы: