3. Safety 

 
These operating instructions contain basic hints to be observed during installation, operation and 
maintenance. Therefore, prior to mounting and commissioning, these operating instructions must by 
all means be read by the fitter as well as the pertinent expert personnel/customer and must always be 
available at the place of installation of the pump. Not only are the general safety hints listed under this 
item “Safety” to be observed, but also the special safety hints in other chapters. 

 

3.1. Labels at the pump 

Marking labels at the pump e.g.  
- pmax 4 bar 
- Fluid connections 
- Direction of flow  
must not be removed and has to be readable. 

 

3.2. Qualification of the personell 

The customer is responsible for ensuring that all maintenance, inspection and 
mounting operations are performed by authorized and qualified expert personnel who 
have sufficiently informed themselves by thoroughly studying the operating 
instructions. 

 

3.3. Responsible working 

Please follow strictly the safety guidelines of this manual, as well as all national and 
possible internal regulations (e.g. the handling of chemicals, like caustic or acid, the 
handling of biological materials, the handling of tubing, piping, instrumentation, fittings 
etc. 

 

3.4. Dangers in case of noncompliance with the safety instructions 

In case of non-compliance with the safety instructions may cause danger to 
personnel, equipment and environment. 

 

 

It can cause for example: 

o

  Failure of the proper function of the pump/system 

o

  Failure of required procedures for maintenance  

o

  Danger to personnel by electrical, mechanical, chemical, biological impacts 

o

  Danger to equipment and environment through leakage of dangerous substances 

 

3.5. Safety hints for the operator

 

o

  In case of hot parts (e.g. while CIP or SIP) protective measures have to be taken. 

o

  Protecting covers of moving parts (e.g. coupling, cover of motor, cover of drive 

belt) must not be removed. 

o

  Leakages of dangerous products have to be handled without any danger for 

persons and environment. Statutory regulations must be observed.  

o

  Dangers by electrical energy are to be excluded (for details please refer to the 

regulations of the VDE and the local energy supply associations) 

 
 
 
 
 
 
 
 
 
 

 

Содержание 5050SU

Страница 1: ...aternary Pump With Polypropylene Pump Chamber Single Use Please read this manual carefully before start up of the pump and take care of an appropriate instruction of the operating staff Attention Plea...

Страница 2: ...structions 7 3 5 Safety hints for the operator 7 3 6 Safety instructions for maintenance inspection and mounting operations 8 3 7 Unauthorized reconstruction and spare part usage 8 3 8 Inadmissible mo...

Страница 3: ...dness dirtying UV radiation and mechanical influences The following storage conditions are recommended Steady ventilated dust and vibration free storage room Ambient temperature between 15 C 59 F and...

Страница 4: ...dges or plate and frame depth filters Chromatography Packing of chromatography columns Feed pump to mix gradients Feed pump for centrifuges or separators Feed pump for homogenizers Feed pump for filli...

Страница 5: ...ck with appropriate analytical methods the success of the flushing procedure Recommendation Test run prior first use Before using your pump in your process perform a test run to get used to the specif...

Страница 6: ...ump chamber in a vacuum autoclave at max 130 C 266 F for max 30 min Follow instructions of the autoclave manufacturer 4 After cooling down the screws of the membrane housing cover and the connectors s...

Страница 7: ...the safety guidelines of this manual as well as all national and possible internal regulations e g the handling of chemicals like caustic or acid the handling of biological materials the handling of...

Страница 8: ...tart up and check the tightness of the pump o Please respect the relevant additional security advices if the pump has been used for aggressive dangerous or toxic liquids e g suitable protective equipm...

Страница 9: ...y case if the pump will be the right tool for the specific application The user operator is responsible to perform a proper method of testing if the pump should be applied for his specific application...

Страница 10: ...box or the motor is to be opened only by skilled personnel Check the electrical cables before connecting to mains supply During all maintenance work it has to be ensured that no explosive atmosphere c...

Страница 11: ...verified For corrosion reasons or a clearly audible operating noise the parts of the bearing service kit should be also replaced PSKITWLC44 Tension roller Q531053020 and drive belt Q6158 419 with wea...

Страница 12: ...idation is inapplicable The replacement of the pump chamber can be conducted by the operator Please follow the drawings for the disassembly and assembly Before starting the disassembly ensure that the...

Страница 13: ...sider the following tightening torques during the installation of the pump chamber Picture 1 Step 3 Fastening screws 25 Nm 18 4 lb ft Picture 3 Step 1 Clamp ring screw 5 Nm 3 7 lb ft 1 Push SU pump ch...

Страница 14: ...Tension roller Q531053020 Drive belt Q6158 419 The replacement of the bearing unit can be conducted by the operator The following drawings describe it step by step 7 For mounting the pump chamber to...

Страница 15: ...e liquid to be pumped 8 X X Check pressure head open valve in discharge line completely remove obstruction in discharge line 9 X Pressure line completely or partly clogged diaphragm maybe broken chang...

Страница 16: ...If translation is used Pump rpm motor rpm x reduction ratio 0 10 20 30 40 50 60 70 80 90 100 0 500 1000 1500 2000 2500 3000 3500 4000 4500 5000 5500 6000 0 200 400 600 800 1000 1200 Flow rate L min F...

Страница 17: ...e approx cm inch 1669 259 Speed range pump rpm 1 1285 Connection specification inlet standard Connector 1 5 TC Flange diameter mm inch 50 5 Internal diameter mm inch 34 Connection specification outlet...

Страница 18: ...x height mm inch 234 x 105 x 314 9 21 x 4 13 x 12 36 Weight approx kg lb 8 17 64 All technical data relate to a Quattroflow pump in the standard version Special designed pumps e g special product conn...

Отзывы: