QF5050SU; edition 2016-05; page 13 of 18
4.1.2. Installation of SU pump chamber
Required tools: Allen hex key 10 mm
Torque wrench (5-25 Nm) and hex key inserts with 5 and 8 mm (e.g. from Hazet Tools, order no.
5108-2CT with inserts 8501X-5, 8501X-8 and extension 867-4)
1.
2.
3.
For correct operation it is important to consider the following tightening torques during the
installation of the pump chamber.
Picture 1 Step 3: Fastening screws 25 Nm (18.4 lb-ft)
Picture 3 Step 1: Clamp ring screw 5 Nm (3.7 lb-ft)
1. Push SU pump
chamber on drive
unit
2. Install pressure
plate with 4 screws
3. Fasten the 4 screws
with 25 Nm torque
(18.4 lb-ft)
1. Verify if clamp ring is in close contact with
drive plate
Clamp ring
Drive plate
1. Fasten internal screw of clamp ring
applying a torque of 5 Nm (3.7 lb-ft)
2. Close hole in the ring drive
with screw