Check the current setting
of the timer
RELAYnTIMER
n=1, Relay 1
n=2, Relay 2
For example, by sending “
RELAY2TIMER”
,
the timer setting on reply 2 will be reply to
operator. The replied message will be similar
as
’Port 2 will switch ON at 12:30;00 and
switch OFF at 13:30:00’
Switch off the Timer
setting
GDSn
n=1, Relay 1
n=2, Relay 2
Message ‘Timer on Relay n has switched OFF’
will be returned to the operator if the setting is
successful; where n is ‘
1
’ or ’
2
’.
Note: The local time will not be affected by
switching off the timer.
GPS tracking
Check
the
current
position of the module
DQGPS
Message
similar
as
‘http://maps.google.com/maps?q=51.961718
,-0.269798’
will be returned to the operator if
the setting is successful. By click the replied
link message, G033 module position will be
displayed on Google map.
Monitoring/alarm input
Releases relay status
which is triggered by the
external signals.
EXTRT
After it has been triggered by the external
signals, the related relay will be locked in the
normal state. By sending
‘EXTRT’
, the relays
will be unlocked and available for responding to
SMS commands again.
Disable the function of
been
triggered
by
external signals.
EXTGBn
n=1, Relay 1
n=2, Relay 2
n=3, only available for PIR
wireless PIR detector (QK-
G022P variant)
By sending
‘EXTGBn’
, the external alarm input
n will be disabled. Message ‘Alarm input n has
been disabled.’ will be returned to the operator
if the setting is successful, where n is ‘1’
‘2’or’3’.
By sending ‘
EXTRT
’ all external alarm inputs
will be active.
This disable status doesn’t affect by re-
powering up the module, only
‘EXTRT’
can.
Disable
alarm
alert
message
EXTGGn
n=1, Relay 1
n=2, Relay 2
By sending ‘
EXTGGn’
the alarm notification
message will not be sent from controller. When
and alarm input is recognised the relay will still
function but won’t send a command t the main
sim
Enable
alarm
alert
message
EXTKKn
n=1, Relay 1
n=2, Relay 2
By sending ‘
EXTKKn’
the alarm notification
message will be sent from controller. When
and alarm input is recognised the relay will
work and the device will send a confirmation
message to the users.
G033 has two digital input ports which can be used to monitor external signals. These two external input
ports can accept 0 V to 24.0 V voltage levels. Should the input voltage level be below 1.0 V, the main
mobile terminal will receive the warning message ‘Port n has been triggered’, where n is the relay number.
The relay n will switch to the normal state (NC will be the closed state and NO will be the open state).
Sending ‘EXTRT’ will release the relays and make them available for responding to SMS commands.