Quark-elec Manual

https://www.quark-elec.com

1 of 23

2018

V1.52

QK-G033 GSM/3G SMS Remote Controller

Manual

Features

Remote monitoring and control by mobile phone for 2G or 3G SMS message

Connects to up to 2 alarm inputs and 3 Relay outputs

Automatic alarm by SMS message when alarm input is triggered

Status request and response by SMS

Remote control of 3 Relay outputs by SMS message

Automated control of 2 Relay outputs by SMS message (activated by alarm input)

Scheduled control of 2 Relay outputs by SMS message

Remote manual override

Android and iOS APP interface

Monitor and Control through text message input or phone APP

Up to 4 mobile phones can monitor and control through each unit

In-built clock for programming the switch state

Easy to install and configure via SMS or APP (no PC required)

Compatible with all major 2G and 3G SIM networks

Содержание QK-G033

Страница 1: ...ponse by SMS Remote control of 3 Relay outputs by SMS message Automated control of 2 Relay outputs by SMS message activated by alarm input Scheduled control of 2 Relay outputs by SMS message Remote manual override Android and iOS APP interface Monitor and Control through text message input or phone APP Up to 4 mobile phones can monitor and control through each unit In built clock for programming t...

Страница 2: ...9 9 1 Normal open normal closed wiring options 9 9 2 Daily timer setting 9 9 3 Self lock vs latching mode 10 9 4 Delay time setting on latching mode 11 10 The G033 App 12 10 1 Setup QK Main Controller SIM Number 13 10 2 Register SIM cards 14 10 3 Setting the clock on the QK controller 14 10 4 Check relay working mode 14 10 5 Rename control terminals 15 10 6 Control panel 15 10 7 Alarm log 17 10 8 ...

Страница 3: ...tage signal to input 1 2 Think about length of wires needed to connect 5 Insert your SIM into the G033 device make a note of the SIM number first for reference 6 Connect to power Check LEDs are working correctly Red LED will flash at 1 second intervals once the system has finished initialization It will then stop flashing every time it is operating a command Blue LED LED will flash blue at start u...

Страница 4: ...s who have a requirement to control and or monitor corresponding devices The G033 includes Two digital alarm inputs connections for connection to various inputs to be monitored an alarm SMS can be received when either alarm input is triggered The alarm input can also be set to trigger automated control of the machinery connected to the Relay outputs 1 and or 2 Three relays output connections for c...

Страница 5: ... www quark elec com 5 of 23 2018 V1 52 4 Enclosure The enclosure is made of IP56 Insulation Class 2 plastic External dimensions 145 x 90 x 41 mm Figure 2 GK G033E European version Figure 3 Enclosure drawing Measurements in mm ...

Страница 6: ...ed Please also make sure voicemail is disabled before inserting the SIM card into the module If a pay as you go PAYG SIM card is used it is recommended that users choose to automatically Top Up when the credit falls below a certain limit Some PAYG SIM cards will be de activated by the network if they are not used to make an outgoing voice call or send an SMS text message within a specific period T...

Страница 7: ...device won t show up when WHORED is sent The operator is now ready to use G033 Details about the SMS command and response messages can be found in the Command List Chapter You can control the device by either Manually entering the codes by SMS text message Using the phone APP android and iOS interface Using the APP you simply select the action you want and the APP formulates and sends the SMS mess...

Страница 8: ...3 G033 will send out an SMS to the registered mobile terminals Meanwhile the corresponding relays you set up will also be activated Alarm function can be disabled so as not to activate relay or timer it will still send message to say alarm triggered Alarm input port Corresponding relay number External alarm 1 INT1 Relay 1 External alarm 2 INT2 Relay 2 PIR detector Relay 3 Note the Alarm input func...

Страница 9: ...n the output of relay1 Normal closed position if common and normal closed are wired then relay 1 will be active while the G033 is powered up This is for fail safe systems where the power going off in the G033 will close relay 1 and activate the output of relay 1 It is important to understand that relays wired in normal closed position will operate in the opposite way to Normal open For example the...

Страница 10: ...o the same for latching mode With latching controls the device will return to its normal status after a period of seconds determined by the user This is useful for output devices that don t need or want to be on for a long time after they have been turned on For example alarm horns which might only need to be on for 12 seconds to alert the user Figure 7 Relay working mode configurations Self lock ...

Страница 11: ...lay time settings for relays Hardware versions G033 provide SMS commands in ONOFFRnxxx format to support other delay times from 001 second to 999 seconds n indicates the relay number 1 or 2 xxx means the delay times from 001 to 999 seconds More details about this command can be found at chapter 10 Delay time set as 12 seconds Delay time set as 9 seconds Delay time set as 6 seconds Delay time set a...

Страница 12: ...pp allows for up to two G033 devices to be controlled from a single mobile device To download the app IOS The iOS G033 APP can be downloaded from Apple store Follow the link below https itunes apple com us app gsm sms remote control id905723192 mt 8 Android The latest Android G033 APP can be downloaded from the link below The Android platform should be at least Version 2 1 or higher https www quar...

Страница 13: ...t says Device 1 in the app If you have 2 G033 devices then you can enter the second SIM card number where it says Device 2 The app will save these numbers so you don t have to keep entering them Input the number of the SIM card which is inserted into the G033into Device 1 All command SMS messages will be sent to this number via the APP Check the tick box to the right of the number you would like t...

Страница 14: ...ce the main SIM numbers this allows for the main controller SIM to be reset Once this message is received by the G033 the user will have 10 minutes to register the main SIM 10 3 Setting the clock on the QK controller G033 can automatically execute actions at the time set by the operator To do this the real time clock on the G033 controller must be set This page allows the operator to check and set...

Страница 15: ...ich relays are in the normal open position and which are in the normal closed position 10 5 Rename control terminals The control terminals can be renamed as a meaningful name in APP For example Heater or Cooler The RF switch option has been discontinued and is there for customers still with RF switches Click the white box of the relay or switch that you would like to rename You will receive a pop ...

Страница 16: ...and to the controller The off button operates the relay to the normal closed position Relay 1 and 2 Timer only relays one and two have timer functionality See next step for timer instructions Relay timer settings set the time at which you would like the relay to turn on and off This is a 24 hour format i e 13 55 00 Relay timer set checking Check the current setting of the timer Relay timer reset S...

Страница 17: ...in the app gives you controls for setting small delay timers disabling alarms and there inputs This can also be used for setting the temperature values of the relays and resetting alarms Reset external alarm It will reset the alarm input allowing a command to be received by the G033 This command will usually be followed by either Disable alarm input or relay off command Disable alarm input this wi...

Страница 18: ... useful because for every alarm input triggered The G033 will send a text message to the controllers notifying them of this G033 will not alert the user to the alarms inputs being enabled when this command is sent The G033 will still automatically initiate the corresponding relay Enable alarm alert command enables input alarm alerts being sent to the controllers ...

Страница 19: ... mobile terminals can be paired with G033 For example by sending BD107919157124F the first additional mobile terminal number is 07919157124 has been paired with G033 Similarly BD207909135124F means pairing G033 with the second additional terminal whose number is 07909135124 The message Your number n phone has been registered will be returned by G033 if mobile terminal n is successfully paired Dele...

Страница 20: ... should use SMS to send this message 433 MHz RF module discontinued Switching RF module ON ONRFn n 1 for 1st RF terminals n 2 for 2nd RF terminals n 3 for 3rd RF terminals n 4 for 4th RF terminals G033 will reply with the relay state information in the following format RFn socket is ON where n is the RF terminal number Switching RF module OFF OFFRFn n 1 1st RF terminals n 2 2nd RF terminals n 3 3r...

Страница 21: ... n 1 Relay 1 n 2 Relay 2 n 3 only available for PIR wireless PIR detector QK G022P variant By sending EXTGBn the external alarm input n will be disabled Message Alarm input n has been disabled will be returned to the operator if the setting is successful where n is 1 2 or 3 By sending EXTRT all external alarm inputs will be active This disable status doesn t affect by re powering up the module onl...

Страница 22: ...elay 7A 240 V AC Rated voltage on relay 9 0 V 245 0 V RF main socket power rating 2000 W G033 Frequency bands by region Standard Frequency G033J G033E G033A GSM 2G GSM 850MHz EGSM 900MHz DCS1800MHz PCS1900MHz WCDMA 3G WCDMA 850MHz WCDMA 900MHz WCDMA 1900MHz WCDMA 2100MHz For more technical information and enquiries please go to the Quark elec forum https quark elec com forum For sales and purchasi...

Страница 23: ...ility or liability either to the products user or their estate for any accident loss injury or damage whatsoever arising out of the use or of liability to use this product Quark products may be upgraded from time to time and future versions may therefore not correspond exactly with this manual The manufacturer of this product disclaims any liability for consequences arising from omissions or inacc...