Drive channel redundancy for the E5600 controller drive trays and EF560
flash arrays
Controller-drive trays
Each controller in these controller-drive trays and flash arrays has two drive expansion ports. With
these controller-drive trays and flash arrays, you can cable a storage array so that each drive tray or
drive shelf has two drive paths to the alternate controller if a controller fails or is removed. To
maintain data access in the event of the failure of a controller, an ESM/IOM, or a drive channel, each
ESM/IOM must have a path to each controller.
Redundant path pair on the E5612 and E5624 controller drive trays and EF560 flash arrays
1.
Controller canister A
2.
Drive channel ports (SAS drive expansion connectors)
3.
Controller canister B
4.
Drive channel ports (SAS drive expansion connectors)
Redundant path pair on the E5660 controller drive trays
1.
Controller canister A
2.
Drive expansion ports (SAS drive expansion connectors)
3.
Controller Canister B
4.
Drive expansion ports (SAS drive expansion connectors)
Drive shelf or drive tray cabling | 75
Содержание StorNext QD7000
Страница 1: ...Hardware Cabling Guide StorNext QD7000 Firmware 8 40 xx xx 6 68683 01 Rev A...
Страница 7: ...Preface Hardware Cabling Guide vii...
Страница 10: ...E Series Hardware Cabling Guide December 2017 215 11792_B0 doccomments netapp com...
Страница 11: ......
Страница 90: ...One E5660 controller drive tray and one DE6600 drive tray Drive shelf or drive tray cabling 81...
Страница 106: ...One E2760 controller drive tray and one drive tray Drive shelf or drive tray cabling 97...